Systematic Reviews
Copyright ©The Author(s) 2023.
World J Gastroenterol. Jun 7, 2023; 29(21): 3341-3361
Published online Jun 7, 2023. doi: 10.3748/wjg.v29.i21.3341
Table 1 Characteristics of studies reporting lumen-apposing metal stents misdeployment during endoscopic ultrasound-guided choledochoduodenostomy
Ref.
Study design
Study population (n)
Clinical indication
Technical success (%)
LAMS misdeployment (n)
LAMS type
Size of LAMS (mm)
Use of guidewire
LAMS flange misdeployed
Rescue therapy
Anderloni et al[20], 2019Retrospective single center46MBO93.53Hot Axios-NoDistal (1/3), not specified (2/3)Rendezvous technique with transpapillary placement of 10 mm × 40 mm FCSEMS after advancing a guidewire through the existing fistula into the bile duct and then across the papilla (1/3); 10 mm × 10 mm LAMS placement through the existing fistula (1/3); double-pigtail plastic stent placement across the LAMS (1/3)
Di Mitri R et al[21], 2022Retrospective single center31MBO80.67Hot Axios8 mm × 8 mm (6/7) 10 mm × 10 mm (1/7)YesDistalOver-the-wire FCSEMS placement (5/7); transpapillary percutaneous-transhepatic-endoscopic rendezvous (1/7); transpapillary laparoscopic-endoscopic rendezvous (1/7)
Rajadurai et al[22], 2022Retrospective multicenter66MBO90.96Hot Axios-No (4/6). Yes (2/6)DistalOver-the-wire FCSEMS placement (2/6); laparotomy (2/6); EUS-GBD (1/6); palliation due to rapid deterioration (1/6)
Jacques et al[23], 2019Retrospective multicenter52MBO88.54Hot Axios--Distal (1/4), proximal (1/4 intraperitoneal, 2/4 intraparietal)Stent-in-stent strategy with SEMS (1/4); ERCP rendezvous (1/4); repeat classic EUS-CDS with SEMS (2/4)
Jacques et al[24], 2020Retrospective multicenter70MBO98.61Hot Axios--No evidence of bile flow even if stent was correctly in situStent-in-stent strategy
El Chafic et al[25], 2019Retrospective multicenter67MBO95.52Hot Axios-Yes-Over the same guidewire FCSEMS placement (all)
Fugazza et al[26], 2022Retrospective multicenter256MBO93.317Hot Axios---Over the guidewire SEMS placement (10/17); deployment of a second LAMS (4/17); EUS-guided rendezvous with subsequent placement of a transpapillary stent (3/17)
Hindryckx and Degroote[27], 2021Retrospective single center13-92.31Hot Axios8 mm × 6 mmYesDistalClip closure of duodenal defect and new EUS-CDS with 8 mm × 6 mm LAMS
Armellini et al[28], 2023Case report1Difficult biliary lithiasis-1Hot Axios8 mm × 8 mmYesDistalRendezvous technique with transpapillary placement of FCSEMS after advancing a guidewire directly through the LAMS and choledochal breach into the bile duct and then across the papilla
Teoh et al[29], 2021Prospective multicenter26MBO88.53Cold spaxus-YesEntirely into the bile ductOver the guidewire SEMS placement
Fugazza et al[30], 2020Case report1Pancreatic adenocarcinoma-1Axios6 mm × 8 mmYesProximalStent-in-stent strategy using SEMS
Brückner et al[31], 2015Case series5MBO801Cold Axios6 mm × 8 mmYesDistalOver the guidewire stent placement
Vanella et al[32], 2023Retrospective study of prospectively maintained databases93MBO97.84Hot Axios-NoDistal (2/4); misdeployments after both flanges release (2/4)Repeat EUS-CDS (1/4); inserting a guidewire through the LAMS catheter followed by over the guidewire LAMS placement (1/4) (the effective rescue therapies were counted as technical success); PTBD (2/4)
de Benito Sanz et al[33], 2021Retrospective single center37MBO1004---Distal (2/4); not specified (2/4)Stent-in-stent strategy (the effective rescue therapies were counted as technical success)
Garcia-Sumalla et al[34], 2021Retrospective multicenter41MBO95.12Hot Axios--No evidence of bile flow even if stent was correctly in situ; distal flangeStent-in-stent strategy using SEMS; rendezvous technique with placement of a transpapillary FCSEMS
Sanchez-Ocana et al[35], 2022Case report1Pancreatic adenocarcinoma-1Axios8 mm × 8 mmYesDistalEUS-guided gallbladder drainage as a portal for antegrade transcystic guidewire passage, followed by rendezvous ERCP with placement of a biliary metal stent and clips to seal the perforation
Graves et al[36], 2021Case report1Pancreatic metastasis of renal cell carcinoma-1Axios10 mm × 10 mmNoDistalA bridging 10 mm × 8 mm FCSEMS was deployed over the guidewire and through theccessing LAMS
Chin et al[37], 2020Retrospective analysis of a prospectively maintained database56MBO1001Axios---Over the guidewire tubular biliary stent placement (the effective rescue therapy was counted as technical success)
On et al[38], 2022Retrospective multicenter120MBO90.87Hot Axios-No (4/7). Yes (3/7)-Bridging stents (5/7), PTBD (1/7), conservative management (1/7)
Ligresti et al[39], 2018Case report1Pancreatic adenocarcinoma-1Axios8 mm × 8 mmYesDistalReinsertion of the delivery system over the guide wire and second deployment of distal flange into common bile duct under EUS guidance