Minireviews
Copyright ©The Author(s) 2021.
World J Gastroenterol. Jun 21, 2021; 27(23): 3290-3302
Published online Jun 21, 2021. doi: 10.3748/wjg.v27.i23.3290
Table 1 Parameters of viscoelastic tests numerical

ROTEM
TEG

Clotting initiationCT (clotting time)R (reaction time)Enzymatic coagulation
Clot kineticsCFT (clot formation time); α angleK (K time); α angleSpeed to reach a certain level of clot strength; Rapidity of fibrin synthesis
Clot strengthMCF (maximum clot firmness)MA (maximum amplitude)Ultimate strength of the fibrin clot
Clot stabilityCLI30 (clot lysis index at 30 min after MCF); CLI60 (clot lysis index at 60 min after MCF)Ly30 (clot lysis at 30 min after MA); Ly60 (clot lysis at 60 min after MA)Clot lysis