Table 1 Quality indicators that can be impacted by bowel preparation in colonoscopy
IndicatorDefinitionAcceptable level
Bowel preparationProportion of procedures in which colon cleansing is considered excellent or good> 90%
Adenoma detection rateProportion of colonoscopies performed in asymptomatic individuals over 50 in which at least one adenoma has been detected> 20%
(men > 25% and women > 15%)
Withdrawal timeMean time from cecal intubation to colonoscopy extraction through the anus> 6 min
Cecal intubation rateProportion of procedures in which cecal intubation is achieved> 95%