Table 3 Cannulation outcomes
| Item (n = 50) | Value |
| Success, n (%) | 45 (90) |
| < 5 min | 38 (76) |
| 5-10 min | 7 (14) |
| Time to selective biliary cannulation1, s | 42.5 (5.0-262.0) |
| No. of attempts1 | 2.0 (1.0-6.0) |
| No. of accidental pancreatic duct insertion1 | 1.0 (0.0-3.0) |
| Amylase level1, IU/L | 148 (94-331) |
| Post-ERCP pancreatitis, n (%) | 3 (6) |
| Mild | 3 |
| Severe | 0 |
| Hyperamylasemia, n (%) | 4 (8) |
- Citation: Omuta S, Maetani I, Shigoka H, Gon K, Saito M, Tokuhisa J, Naruki M. Newly designed J-shaped tip guidewire: A preliminary feasibility study in wire-guided cannulation. World J Gastroenterol 2013; 19(28): 4531-4536
- URL: https://www.wjgnet.com/1007-9327/full/v19/i28/4531.htm
- DOI: https://dx.doi.org/10.3748/wjg.v19.i28.4531