Table 4 Comparison of standard vs high definition adenomatous polyp detection studies to date
StudyDateMethodnColonoscope (resolution) (Angle) (NBI capable)
P value for adenomadetection rates
Group 1Group 2
East et al[13]2008Prospective nonrandomized130Olympus SD 140Olympus HD 1400.200
Pellise et al[12]2008Prospective randomized620Olympus SD 140Olympus HD 1700.850
Tribonias et al[14]2010Prospective randomized390Olympus SD 140Olympus HD 1700.160
Burke et al[16]2010Retrospective852Olympus SD 140Olympus HD 1700.360
Buchner et al[15]2010Retrospective2430Olympus SD 140Olympus HD 170 NBI0.012