BPG is committed to discovery and dissemination of knowledge
Review
Copyright: ©Author(s) 2026.
Artif Intell Gastroenterol. Nov 8, 2026; 7(3): 125000
Published online Nov 8, 2026. doi: 10.35712/aig.125000
Table 5 Studies evaluating applications of artificial intelligence in pancreatic diseases
Ref.
Clinical application
Data type
AI method
Sample size
Study design, center design, and validation design
Major performance metric
Principal limitation
Mukherjee et al[82]PDAC predictionPrediagnostic CT scansSVM420 CT scans, 155 prediagnostic, 265 controlsRetrospective case-control, internal test set, independent internal and external NIH sets, internal and external validationAUC 0.98 (95%CI: 0.94-0.98), accuracy 92.2% (internal validation), specificity 96.2% (external validation), outperformed radiologists (mean AUC 0.66)Retrospective design, small external validation cohorts
Mukherjee et al[83]PDAC predictionStandard-of-care CT scansEnsemble with logistic regression, random forest, and XGBoost1462 scans, 969 training and 493 testRetrospective, multicenter, independent test set and external specificity validation cohortsAUC 0.82 (95%CI: 0.81-0.83), sensitivity 73.0%, specificity 81.1% (internal validation), 81.3% specificity (external validation)Retrospective design, prospective validation in high-risk cohorts is required
Alves et al[84]PDAC detectionRoutine CT scansDL3440 patients, 2224 for training, 86 for tuning, 1130 for sequestered test, multi-reader substudy of 391 cases assessed by 68 radiologistsInternational multicenter observational study, sequestered testing cohort and radiologist subsetMean AUROC 0.92 (95%CI: 0.90-0.93) (external validation), AI performance was statistically superior to the 68-radiologist comparison (P < 0.001)Observational design, results represent average radiologist performance
Placido et al[85]Pancreatic cancer predictionHealth records with ICD codesTransformer and GRU9.2 million patients from DNPR and US-VARetrospective cohort, random 10% test split and cross-application between health systems, internal and cross-validationAUROC 0.88 in Denmark and 0.78 in US-VA (internal validation), Danish model on US-VA dataset yielded AUROC 0.71Performance declined when applied across different healthcare systems
Kuwahara et al[88]IPMN classificationEUS digital still imagesDL with ResNet5050 patients, 3970 imagesRetrospective single-center, 10-fold cross-validationAccuracy 94.0%, AUC 0.98, diagnostic accuracy 94.0% vs 56.0% for human preoperative diagnosisSmall sample size, retrospective design, only surgical cases included
Kurita et al[89]Pancreatic cystic lesion classificationCyst fluid markers and clinical dataDL with TensorFlow85 patientsRetrospective, single-center, observational study, 5-fold cross-validationAUROC 0.966, accuracy 92.9%, AI outperformed cyst-fluid carcinoembryonic antigen (AUROC 0.719) and cytology (AUROC 0.739)Small sample size, single-center study, subjective input factors
Machicado et al[90]IPMN classificationnCLE video framesCNN35 patients, 15027 framesPost hoc analysis of a prospective multicenter cohort, performance on post hoc video data, internal validationAccuracy 82.9%-85.7%, sensitivity 83.3%Small patient cohort, limited to pathologically confirmed cases
Yuan et al[91]Pancreatic cystic neoplasm malignancy predictionContrast-enhanced CT scansMamba U-Net and XGBoost1835 patients, 1249 primary cohort (999 training, 250 validation), external test sets of 173, 289 and 124 patientsMulticenter retrospective and prospective study, external test sets and prospective real-world cohort, internal and external validationAUC 0.845-0.988 (external validation), malignancy detection 81.8% (prospective validation), interpretation time reduced 23.7%, and workload reduced 39.3%Focused on intralesional features, did not incorporate peripancreatic findings
Duh et al[92]Pancreatic cystic lesion classificationAbdominal CT scansAttention Gate U-Net335 abdominal CT scans, 297 pancreatic cystic lesions and 38 controls, training 241 scans/93 patients, independent test 94 scans/43 patientsRetrospective single-center, independent testing set of 94 scans, internal validationSensitivity 93.1%, specificity 81.8%Single-center design, small control cohort, lacks external validation


Write to the Help Desk