Copyright: ©Author(s) 2026.
Artif Intell Gastroenterol. Nov 8, 2026; 7(3): 125000
Published online Nov 8, 2026. doi: 10.35712/aig.125000
Published online Nov 8, 2026. doi: 10.35712/aig.125000
Table 2 Studies evaluating applications of artificial intelligence in gastric diseases
| Ref. | Clinical application | Data type | AI method | Sample size | Study design, center design, and validation design | Major performance metric | Principal limitation |
| Shichijo et al[32] | Detection of H. pylori infection | Endoscopic images (WLI) | 22-layer deep CNN with GoogLeNet | 32208 images (development), 11481 images from 397 patients (test) | Retrospective, single-center, independent test set comparison | Accuracy: 87.7%, 11481 images analyzed in approximately 3.2 minutes vs approximately 230 minutes by endoscopists | Single-center study |
| Liu et al[35] | Kyoto gastritis classification | Gastric endoscopy images (WLI and NBI) | Five GAM-EfficientNet models | 29013 images from 2087 patients, test set of 528 images, compared with 10 endoscopists | Retrospective, single-center, internal training, validation, and testing sets | Average accuracy: 78.70% | Single-center study, imbalanced sample distribution, lack of paired histological validation |
| Hirasawa et al[36] | Gastric cancer detection | Endoscopic images (WLI, chromoendoscopy and NBI) | CNN with Single Shot MultiBox Detector | 13584 training images, 2296 test images | Retrospective, multicenter training, independent test set of consecutive patients | Sensitivity: 92.2%, detected 100% of invasive cancers and 98.6% of lesions ≥ 6 mm, processed 2296 images in 47 seconds | Test set included only cancer cases with high disease prevalence, single endoscope type used |
| Ikenoyama et al[37] | Early gastric cancer detection | Endoscopic images (WLI) | CNN with Single Shot MultiBox Detector | 13584 training images, 2940 test images | Retrospective multicenter training, single-center test set, independent comparison with 67 endoscopists | Sensitivity: 58.4% (95%CI: 51.4%-65.1%) in independent external test set, reading time 45.5 seconds vs 173 minutes for endoscopists | Test set limited to a single center and still images, low PPV of 26.0% |
| Luo et al[38] | Esophageal and gastric cancer detection | Endoscopy images (WLI) | Deep learning with GRAIDS | 1036496 images from 84424 individuals | Multicenter case-control diagnostic study, internal, prospective, and external validation | Accuracy: 0.915-0.977 (external validation sets) | Only standard WLIs were used |
| Zhang et al[40] | Early gastric cancer detection | Gastroscopic images | Improved Mask R-CNN | 1120 images of EGC (140 healthy, 980 EGC cases) | Retrospective, single-center, fivefold cross-validation and testing dataset | Accuracy: 93.9% (internal validation and testing dataset) | Small primary dataset from a single center, generalizability requires further verification |
| Bang et al[39] | Prediction of submucosal invasion in gastric neoplasms | WLI endoscopic images | Automated DL | 2899 training images, 1597 prospective test images | Multicenter validation, training from one hospital and testing at another, prospective multicenter external test | Accuracy: 89.3% (95%CI: 85.1%-93.5%) (external validation), AI-assisted trainee accuracy 81.6% vs 68.4% without AI | Training images from a single institution |
| Gong et al[42] | Gastric neoplasm detection and classification | Real-time endoscopy | DL clinical decision support system | 5017 training images, 2524 pilot procedures | Randomized pilot study and prospective multicenter external test | Classification accuracy: 81.5% (prospective multicenter external test) | Improvement in real-time lesion detection rate was not statistically significant |
| Wu et al[43] | Gastric neoplasm detection | Real-time white-light endoscopy | DL system | 1812 patients | Single-center tandem RCT | Miss rate: 6.1% with AI vs 27.3% with routine examination | Single-center design, endoscopists were not blinded to randomization |
| Xu et al[44] | Detection of precancerous lesions and adenomas | Digestive endoscopy | ENDOANGEL | Prospective intervention phases | Prospective, randomized, single-center clinical trial | IM detection rate: 14.23% vs 9.15% | Single-center trial design |
| Calder et al[45] | Automated artifact detection and signal recovery in gastric body-surface mapping | High-resolution gastric myoelectrical activity data from BSGM | Automated artifact detection and rejection algorithm with signal recovery | 10 patients, 176 data samples | Prospective validation study, single-center | Accuracy: 95%, sensitivity: 96%, specificity: 95% against expert markers | Small sample size and demographic bias, with all participants being female |
- Citation: Roy SK, Samanta A, Banerjee A. Artificial intelligence in gastroenterology practice: Current perspectives and emerging prospects. Artif Intell Gastroenterol 2026; 7(3): 125000
- URL: https://www.wjgnet.com/2644-3236/full/v7/i3/125000.htm
- DOI: https://dx.doi.org/10.35712/aig.125000