BPG is committed to discovery and dissemination of knowledge
Review
Copyright: ©Author(s) 2026.
Artif Intell Gastroenterol. Nov 8, 2026; 7(3): 125000
Published online Nov 8, 2026. doi: 10.35712/aig.125000
Table 2 Studies evaluating applications of artificial intelligence in gastric diseases
Ref.
Clinical application
Data type
AI method
Sample size
Study design, center design, and validation design
Major performance metric
Principal limitation
Shichijo et al[32]Detection of H. pylori infectionEndoscopic images (WLI)22-layer deep CNN with GoogLeNet32208 images (development), 11481 images from 397 patients (test)Retrospective, single-center, independent test set comparisonAccuracy: 87.7%, 11481 images analyzed in approximately 3.2 minutes vs approximately 230 minutes by endoscopistsSingle-center study
Liu et al[35]Kyoto gastritis classificationGastric endoscopy images (WLI and NBI)Five GAM-EfficientNet models29013 images from 2087 patients, test set of 528 images, compared with 10 endoscopistsRetrospective, single-center, internal training, validation, and testing setsAverage accuracy: 78.70%Single-center study, imbalanced sample distribution, lack of paired histological validation
Hirasawa et al[36]Gastric cancer detectionEndoscopic images (WLI, chromoendoscopy and NBI)CNN with Single Shot MultiBox Detector13584 training images, 2296 test imagesRetrospective, multicenter training, independent test set of consecutive patientsSensitivity: 92.2%, detected 100% of invasive cancers and 98.6% of lesions ≥ 6 mm, processed 2296 images in 47 secondsTest set included only cancer cases with high disease prevalence, single endoscope type used
Ikenoyama et al[37]Early gastric cancer detectionEndoscopic images (WLI)CNN with Single Shot MultiBox Detector13584 training images, 2940 test imagesRetrospective multicenter training, single-center test set, independent comparison with 67 endoscopistsSensitivity: 58.4% (95%CI: 51.4%-65.1%) in independent external test set, reading time 45.5 seconds vs 173 minutes for endoscopistsTest set limited to a single center and still images, low PPV of 26.0%
Luo et al[38]Esophageal and gastric cancer detectionEndoscopy images (WLI)Deep learning with GRAIDS1036496 images from 84424 individualsMulticenter case-control diagnostic study, internal, prospective, and external validationAccuracy: 0.915-0.977 (external validation sets)Only standard WLIs were used
Zhang et al[40]Early gastric cancer detectionGastroscopic imagesImproved Mask R-CNN1120 images of EGC (140 healthy, 980 EGC cases)Retrospective, single-center, fivefold cross-validation and testing datasetAccuracy: 93.9% (internal validation and testing dataset)Small primary dataset from a single center, generalizability requires further verification
Bang et al[39]Prediction of submucosal invasion in gastric neoplasmsWLI endoscopic imagesAutomated DL2899 training images, 1597 prospective test imagesMulticenter validation, training from one hospital and testing at another, prospective multicenter external testAccuracy: 89.3% (95%CI: 85.1%-93.5%) (external validation), AI-assisted trainee accuracy 81.6% vs 68.4% without AITraining images from a single institution
Gong et al[42]Gastric neoplasm detection and classificationReal-time endoscopyDL clinical decision support system5017 training images, 2524 pilot proceduresRandomized pilot study and prospective multicenter external testClassification accuracy: 81.5% (prospective multicenter external test)Improvement in real-time lesion detection rate was not statistically significant
Wu et al[43]Gastric neoplasm detectionReal-time white-light endoscopyDL system1812 patientsSingle-center tandem RCTMiss rate: 6.1% with AI vs 27.3% with routine examinationSingle-center design, endoscopists were not blinded to randomization
Xu et al[44]Detection of precancerous lesions and adenomasDigestive endoscopyENDOANGELProspective intervention phasesProspective, randomized, single-center clinical trialIM detection rate: 14.23% vs 9.15%Single-center trial design
Calder et al[45]Automated artifact detection and signal recovery in gastric body-surface mappingHigh-resolution gastric myoelectrical activity data from BSGMAutomated artifact detection and rejection algorithm with signal recovery10 patients, 176 data samplesProspective validation study, single-centerAccuracy: 95%, sensitivity: 96%, specificity: 95% against expert markersSmall sample size and demographic bias, with all participants being female


Write to the Help Desk