Table 1 Studies evaluating applications of artificial intelligence in esophageal diseases
Ref.
Clinical application
Data type
AI method
Sample size
Study design, center design, and validation design
Major performance metric
Principal limitation
Pace et al[8]GERD vs controls, EE vs NERD discriminationQUID questionnaire (clinical/symptom data)ANN, TWIST evolutionary algorithm577 patients, 94 controlsProspective, multicenter (60 centers), resampling-based training, testing, and validationAccuracy: 99.2% for GERD vs controls, 66.5% for EE vs NERDPoor discrimination between EE and NERD
Huang et al[11]GERD diagnosisEndoscopic images of esophagogastric junctionHHDF-SVM39 patients, 108 controlsDiagnostic accuracy study, single-center, 10-fold cross-validationAccuracy: 93.2%, sensitivity: 94.9%, performance exceeded inexperienced endoscopistsSmall sample size, no automated LA grading
Wang et al[9]LA classification of GERDConventional and NBI endoscopic imagesGERD-VGGNet496 patients, 464 development cohort, 32 external test cohortRetrospective, single-center, 10-fold cross-validation, external test setNBI accuracy: 99.2% internally, 87.5% external testing, external test accuracy exceeded young trainee endoscopistsSmall external test set, overfitting without augmentation
Yen et al[10]LA classification of GERDNBI endoscopic imagesGERD-VGGNet features, random forest671 development images, 32 test imagesRetrospective, single-center, 10-fold cross-validation, independent test setAccuracy: 98.4% internally, 92.5% independent testingRetrospective design, small independent test set
Ge et al[12]Hill classification of gastroesophageal flap valveRGB endoscopic imagesResNet-50, dual attention (EDA + SE)3256 images, 2589 for training, 334 for validation, 333 for testRetrospective, single-center, training, validation, and independent test setsAccuracy: 93.39%, AUC: 0.989Single-center, reduced performance for adjacent categories (Hill II vs III)
Rogers et al[13]Automated baseline impedance and reflux assessmentpH-impedance monitoring dataDecision tree analysis325 individuals, 117 symptomatic off-PPI, 93 symptomatic on-PPI, 115 controlsExploratory observational cohort, multicenter, comparison with manual reference standardsEvent identification accuracy: 88.5%, AUC: 0.766 for treatment-response prediction, calibration: regression agreement with manual MNBI, r2 = 0.79-0.86Proof-of-concept, excluded very low baseline impedance cases
Zhou et al[14]Reflux event identification24-hour pH-impedance monitoringStructured State Space (S4) model45 patients, 25 for training, 20 for testRetrospective, single-center, training, validation, and independent test setsAUC: 0.87 (95%CI: 0.85-0.89), specificity: 80.8%, threshold calibrated to expert false-positive rateSmall sample size, relatively limited sensitivity
Wong et al[15]Reflux episodes and PSPW index assessment24-hour impedance-pH monitoringDeep residual network (ResNet)106 patientsRetrospective analysis, single-center, validation against manual Wingate criteriaAccuracy: 87% for reflux episodes, 82% for PSPW index, calibration: manual Wingate criteria used as reference standardClinical adjunct, manual analysis remains necessary
Rosenfeld et al[16]BE detection/risk predictionQuestionnaire (symptoms/risk factors)Logistic regression with IG and CFS feature selection1299 (BEST2/training and internal validation), 398 (BOOST/external validation)Case-control, multicenter, internal split-sample, external independent cohortTraining AUC: 0.87 (95%CI: 0.84-0.90), internal: 0.86 (95%CI: 0.83-0.89), external: 0.81 (95%CI: 0.74-0.84), calibration: Probability output calibrated to 90% sensitivity, log-loss/precision-recall assessedCase-control enrichment may overestimate performance, requires prospective primary-care validation
Iyer et al[17]BE and EAC predictionEHRsEnsemble transformer-based ML model8476 BE cases, 1539 EAC cases, 252276 controlsRetrospective cohort, multicenter, 10% model holdout setAUROC: 0.84 for both BE and EACLimited explainability, requires validation outside Mayo Clinic EHR systems
Berman et al[18]BE segment length predictionDigitized whole-slide images (Cytosponge-TFF3)CNN for tile identification, logistic regression529 (BEST2), 158 (BEST3)Case-control, RCT evaluation, multicenter, 5-fold cross-validation, independent RCT cohortInternal accuracy: 0.84 (95%CI: 0.77-0.90), precision: 0.95 (95%CI: 0.87-1.00), RCT precision: 0.91 (95%CI: 0.85-0.97), clinically relevant BE: 55% could avoid gastroscopy, false-negative rate 5.1%Small independent test set, 5.1% false-negative rate for clinically relevant BE
Faghani et al[19]Histological dysplasia classification (NDBE, LGD, HGD)Digitized histology whole-slide imagesEnsemble deep learning (YOLO, ResNet101)542 patients, 70% for training, 20% for validation, 10% for testRetrospective validation, random 70/20/10 train/validation/test splitLGD sensitivity: 81.3%, specificity: 100%, NDBE/HGD > 90%, F1-score: 0.90-1.0Pilot-scale validation, real-world community pathology performance unknown
Gao et al[20]ESCC and esophagogastric junction adenocarcinoma risk prediction105 cytological, 15 epidemiological featuresAutomated ML-based prediction tool17498 eligible participantsNationwide, multicohort, prospective, multicenter (39 hospitals), internal testing, community-based validationInternal AUROC: 0.960 (95%CI: 0.937-0.977), prospective AUROC: 0.964 (95%CI: 0.920-0.990), clinically: Unnecessary endoscopies avoided in 90.3% of the testing cohort and 92.8% of community screening participantsPrimarily focused on resource optimization for endoscopy in China
Fockens et al[21]Detection of early Barrett’s neoplasiaWhite-light endoscopic images and videosEfficientNet-Lite1 encoder, MobileNetV2 DeepLabV3+ decoder14046 images from 2506 patients for trainingModel development and validation, multicenter (15 international centers), all-comers and enriched benchmarking test setsSensitivity: 95% (95%CI: 88%-98%) for images, 97% (95%CI: 90%-99%) for videos in all-comers setTraining relied on high-quality expert images, subtle neoplastic lesions were scarce
Yuan et al[22]Detection and delineation of superficial ESCC and precancerous lesionsNon-magnified NBIAI-based detection and delineation system10047 still images and 140 videos (1112 patients)Multicenter development and validation, multicenter (4 hospitals), internal/external image test sets and prospective clinical evaluationAccuracy: 92.4% internal, 89.9% external, 91.4% prospectiveAccurate delineation of lesion margins remains a key clinical challenge
Chempak Kumar et al[23]Classification and staging of ESCC, EAC, and BEEndoscopic imagesMulti-CNN (Xception, MobileNetV2, GoogLeNet, Darknet53), ABC optimization, SVM1028 images (523 BE, 217 ESCC, 288 EAC)CAD network development, single-center, 3-fold cross-validationOverall classification accuracy: 97.76%Relatively small dataset
Lu et al[24]Prognostic prediction in ESCC27 clinical and laboratory blood parametersRandom survival forest2521 consecutive patients, 1765 for training and 756 for testRetrospective, single-center, 70% training/30% test splitC-index: 0.746, 5-year AUC: 0.771Single-region cohort, retrospective design limits generalizability
Popa et al[25]Classification of esophageal motility disordersSingle wet-swallow raw HREM imagesDL (CNN, Inception V3)157 patients (1570 images), 70% training, 15% testing, 15% validationRetrospective, single-center, 70% training/15% testing/15% validationOverall accuracy: 94% (validation dataset)Small sample size, diagnosis-purity bias from exclusion of complex cases
Takahashi et al[26]Prediction of persistent symptoms and reflux esophagitis after POEM in achalasiaDemographic data, disease duration, HRM, esophagographyML clustering and predictive models1824 treatment-naïve patients including 1778 undergoing POEMMulticenter cohort, model development for risk stratificationAUC: 0.70 for persistent symptoms, 0.61 for reflux esophagitisWeak predictive performance for post-POEM reflux esophagitis
Carlson et al[27]Classification of achalasia subtypes using FLIP panometryFLIP panometrySupervised ML (decision trees)180 adult patientsRetrospective analysis of a prospective cohort, single-center, 140 training/40 test cohortSpastic accuracy: 90%, non-spastic accuracy: 78%Marked reduction in test-set accuracy, limited generalizability due to human-scored variables
Wang et al[28]GEV segmentation and RC sign detectionEndoscopic images and videosENDOANGEL-GEV (U-Net++, DCNN, DBSCAN)1156 training patients, 161 prospective patientsMulticenter retrospective with prospective observational, internal, multicenter video, and prospective validationEV segmentation mIoU: 0.8087 (95%CI: 0.7968-0.8206), prospective RC detection accuracy: 94.62% (95%CI: 89.11%-97.56%), clinical impact: Correct prophylactic intervention in 12.3% additional patients and avoidance of unnecessary prophylaxis in 52.6% low-risk patientsSingle-arm design, potential bias from high proportion of severe Child-Pugh C cases
Chen et al[29]GEV detection and classificationEndoscopic images and videosENDOANGEL (DCNN)6189 patients with 14718 imagesMulticenter retrospective, independent image and multicenter video validationEV detection accuracy: 97.00%, GV detection accuracy: 92.00%Focused mainly on detection/classification, lacked later interpretable logic
Hong et al[30]Prediction of 12-month EV bleedingEndoscopic imagesDL (transfer learning with EfficientNet)1075 images (675 training/validation, 400 test)Multicenter retrospective cohort, internal and external validationEfficientNet accuracy: 0.893, recall: 0.870Reliance on single endoscopic images rather than multiple views or clinical data
Wang et al[31]Prediction of 12-month EV bleedingEndoscopic images and clinical structured dataMMML stacking model (EfficientNet + 6 algorithms)341 patients, 161 patients in the external test cohortMulticenter retrospective cohort, internal validation and external testingAUC: 0.975, sensitivity: 0.952No comparison with Baveno criteria, no elastography data, limited sample size