Copyright: ©Author(s) 2026.
World J Nephrol. Jun 25, 2026; 15(2): 120396
Published online Jun 25, 2026. doi: 10.5527/wjn.v15.i2.120396
Published online Jun 25, 2026. doi: 10.5527/wjn.v15.i2.120396
Table 2 Factors associated with carotid intima-media thickness in dialysis patients (n = 83)
| Variables | Coefficient (β) | Standard error | t-value | 95%CI | P value |
| Age, year | 0.006 | 0.002 | 3.078 | 0.002-0.009 | 0.0031,a |
| Hemoglobin, g/dL | 0.002 | 0.010 | 0.211 | -0.018 to 0.022 | 0.833 |
| NLR | -0.006 | 0.011 | -0.547 | -0.029 to 0.017 | 0.586 |
| Albumin, g/dL | 0.004 | 0.018 | 0.189 | -0.034 to 0.041 | 0.851 |
| Calcium, mg/dL | 0.000 | 0.006 | 0.076 | -0.011 to 0.012 | 0.940 |
| FGF-23/Klotho ratio | -0.050 | 0.080 | -0.563 | -0.229 to 0.128 | 0.575 |
| FGF-23, pg/mL | 0.053 | 0.249 | 1.641 | -0.011 to 0.118 | 0.105 |
| iPTH, pg/mL | -0.025 | 0.024 | -1.039 | -0.074 to 0.023 | 0.302 |
- Citation: Samsu N, Hayati M, Winoto ES, Susianti H. Comparison of carotid intima-media thickness between hemodialysis and peritoneal dialysis patients. World J Nephrol 2026; 15(2): 120396
- URL: https://www.wjgnet.com/2220-6124/full/v15/i2/120396.htm
- DOI: https://dx.doi.org/10.5527/wjn.v15.i2.120396