BPG is committed to discovery and dissemination of knowledge
Prospective Study
©The Author(s) 2025.
World J Exp Med. Dec 20, 2025; 15(4): 108702
Published online Dec 20, 2025. doi: 10.5493/wjem.v15.i4.108702
Table 3 Distribution of retinal nerve fiber layer and ganglion cell complex thickness at baseline and follow-up visits, mean ± SD
Retinal nerve fiber layer thickness (micron)
Pre-operative
At discharge
After 1.5 months
After 3 months
After 6 months
Superior 110.19 ± 60.94 107.16 ± 43.8497.28 ± 31.1997.38 ± 29.1698.54 ± 31.98
Inferior 107.25 ± 53.04 102.84 ± 34.2595.87 ± 32.1693.58 ± 32.0795.97 ± 31.04
Nasal 68.04 ± 31.8565.79 ± 22.8861.53 ± 16.1360.78 ± 15.4161.83 ± 16.58
Temporal 51.51 ± 19.2550.72 ± 12.2951.16 ± 12.151.38 ± 10.3251.91 ± 9.97
Ganglion cell complex thickness (micron)65.67 ± 14.8564.85 ± 15.2365.26 ± 13.6965.43 ± 15.5966.19 ± 15.62