Copyright: ©Author(s) 2026.
World J Gastrointest Surg. Aug 27, 2026; 18(8): 117878
Published online Aug 27, 2026. doi: 10.4240/wjgs.117878
Published online Aug 27, 2026. doi: 10.4240/wjgs.117878
Table 3 Domain-specific multivariable analysis of strategy selection-related factors
| Characteristics | Success/failure | P value | Exp(B) | 95%CI for Exp(B) | |
| Timing | 0.300 | ||||
| Emergency | 56/30 | 0.757 | 0.447 | 1.282 | |
| Elective | 192/77 | 1.321 | 0.78 | 2.237 | |
| Location | 0.672 | ||||
| Operating room | 129/50 | 1.155 | 0.593 | 2.25 | |
| Puncture room | 81/40 | 0.863 | 0.43 | 1.732 | |
| Bedside | 38/17 | 0.866 | 0.444 | 1.687 | |
| Angle | 0.835 | ||||
| 45°-135° | 185/80 | 0.945 | 0.556 | 1.607 | |
| Other | 63/27 | 1.058 | 0.622 | 1.799 | |
| Length | 0.649 | ||||
| ≥ 12 (cm) | 63/30 | 1.129 | 0.67 | 1.901 | |
| < 12 (cm) | 185/77 | 0.886 | 0.526 | 1.492 | |
| Position | 0.598 | ||||
| Right side | 31/12 | 1.214 | 0.59 | 2.497 | |
| Left side | 217/95 | 0.824 | 0.4 | 1.695 | |
| Ultrasound probe | 0.026 | ||||
| Conventional | 198/96 | 0.451 | 0.223 | 0.911 | |
| Puncture-specific | 50/11 | 2.219 | 1.098 | 4.486 | |
| Catheter diameter | 0.440 | ||||
| ≤ 8 French | 191/78 | 0.812 | 0.478 | 1.379 | |
| > 8 French | 57/29 | 1.232 | 0.725 | 2.094 | |
| Operator change | 0.762 | ||||
| Yes | 8/1 | 1.242 | 0.306 | 5.04 | |
| No | 47/34 | 0.805 | 0.198 | 3.267 | |
| Target change | 0.101 | ||||
| Yes | 6/4 | 5.962 | 0.704 | 50.501 | |
| No | 49/31 | 0.168 | 0.02 | 1.421 | |
- Citation: Song Y, Chen GH, Peng L, Du J, Tan SM. Predictors of the technical success of ultrasound-guided percutaneous transhepatic biliary drainage for biliary obstruction. World J Gastrointest Surg 2026; 18(8): 117878
- URL: https://www.wjgnet.com/1948-9366/full/v18/i8/117878.htm
- DOI: https://dx.doi.org/10.4240/wjgs.117878