Copyright: ©Author(s) 2026.
World J Gastrointest Surg. Mar 27, 2026; 18(3): 115349
Published online Mar 27, 2026. doi: 10.4240/wjgs.v18.i3.115349
Published online Mar 27, 2026. doi: 10.4240/wjgs.v18.i3.115349
Table 1 Level 1 and level 2 indicators and weights of the safety handover management system
| Primary indicator and weight | Secondary indicator and weight | Composite weight |
| A1: Pre-handover preparation (0.3512) | B1: Completeness of patient information preparation (0.4015) | 0.1411 |
| B2: Preparation of drugs/supplies/equipment (0.3287) | 0.1155 | |
| B3: Environment and personnel readiness (0.2698) | 0.0948 | |
| A2: Handover process execution (0.4635) | B4: Accurate patient identification (0.2150) | 0.0997 |
| B5: Completeness of intra-operative status transfer (0.1832) | 0.0849 | |
| B6: Handover of vital signs and level of consciousness (0.1714) | 0.0794 | |
| B7: Tubing check and secure fixation (0.1555) | 0.0721 | |
| B8: Fluid balance and medication summary (0.1349) | 0.0625 | |
| B9: Skin integrity and belongings transfer (0.0751) | 0.0348 | |
| B10: Special issues and key medical orders (0.0649) | 0.0301 | |
| A3: Post-handover verification (0.1853) | B11: Information recheck and clarification of doubts (0.6328) | 0.1172 |
| B12: Mutual signature and documentation (0.3672) | 0.0681 |
- Citation: Hu J, Yang WW, Qin W, Ren TT, Zhang MX, Zhu Q. Developing a standardized safety handover system for post-anesthesia patients in gastrointestinal surgery: Construction and validation. World J Gastrointest Surg 2026; 18(3): 115349
- URL: https://www.wjgnet.com/1948-9366/full/v18/i3/115349.htm
- DOI: https://dx.doi.org/10.4240/wjgs.v18.i3.115349