Table 6 Diagnostic efficacy of gemstone spectral computed tomography imaging-related indicators via receiver operating characteristic curve analysis
Indicators | AUC | P value | 95%CI | Threshold | Sensitivity | Specificity |
Axial short diameter | 0.631 | < 0.001 | 0.564-0.699 | 1.28 cm | 83.48% | 48.00% |
Sagittal short diameter | 0.681 | < 0.001 | 0.615-0.746 | 1.14 cm | 95.65% | 48.67% |
Coronal short diameter | 0.659 | < 0.001 | 0.592-0.725 | 1.15 cm | 86.09% | 51.33% |
IC in arterial phase | 0.862 | < 0.001 | 0.817-0.908 | 21.50 100 μg/cm3 | 72.17% | 84.00% |
IC in venous phase | 0.808 | < 0.001 | 0.756-0.861 | 27.50 100 μg/cm3 | 67.83% | 80.67% |
NIC in arterial phase | 0.831 | < 0.001 | 0.780-0.882 | 0.22 | 74.78% | 80.00% |
λHU in arterial phase | 0.801 | < 0.001 | 0.742-0.860 | 2.99 | 69.57% | 90.00% |
λHU in venous phase | 0.706 | < 0.001 | 0.644-0.768 | 2.87 | 62.61% | 67.33% |
- Citation: Liu W, Kong DM, An JK, Song LT. Analysis of the clinical value of gemstone spectral computed tomography imaging in the preoperative assessment of colorectal cancer. World J Gastrointest Surg 2025; 17(8): 105391
- URL: https://www.wjgnet.com/1948-9366/full/v17/i8/105391.htm
- DOI: https://dx.doi.org/10.4240/wjgs.v17.i8.105391