Table 3 Comparison of catheter adjustment and radiation exposure between groups, n (%)
| Parameter | Experimental group (n = 103) | Control group (n = 113) | Statistics | P value |
| Catheter adjustment | ||||
| Number of adjustments (times), mean ± SD | 0.27 ± 0.46 | 1.45 ± 1.03 | t = 10.652 | < 0.001 |
| Frequency of adjustments | χ2 = 77.183 | < 0.001 | ||
| 0 time | 76 (73.8) | 21 (18.6) | ||
| 1 time | 25 (24.3) | 40 (35.4) | ||
| ≥ 2 times | 2 (1.9) | 52 (46.0) | ||
| Reasons for adjustment | (n = 23) | (n = 170) | χ2 = 48.216 | < 0.001 |
| Inaccurate position | 0 (0) | 128 (75.3) | ||
| Insufficient length | 15 (65.2) | 25 (14.7) | ||
| Catheter kinking | 8 (34.8) | 17 (10.0) | ||
| X-ray exposure | ||||
| X-ray exposure time (seconds), mean ± SD | 5.3 ± 2.1 | 18.7 ± 4.5 | t = 26.419 | < 0.001 |
| Number of fluoroscopies (times), mean ± SD | 1.1 ± 0.3 | 3.5 ± 0.8 | t = 29.783 | < 0.001 |
| Patients requiring only 1 fluoroscopy | 93 (90.3) | 0 (0) | χ2 = 168.297 | < 0.001 |
| Patients requiring ≥ 3 fluoroscopies | 0 (0) | 59 (52.2) | χ2 = 73.641 | < 0.001 |
| Radiation dose | ||||
| Average radiation dose (μGy·m2), mean ± SD | 14.8 ± 5.6 | 52.4 ± 12.3 | t = 28.937 | < 0.001 |
| Operator scattered radiation dose (μSv/procedure), mean ± SD | 1.2 ± 0.5 | 4.3 ± 1.2 | t = 24.106 | < 0.001 |
| Subgroup analysis (radiation-sensitive population) | n = 15 | n = 17 | - | - |
| X-ray exposure time (seconds), mean ± SD | 4.7 ± 1.8 | 19.5 ± 5.2 | t = 10.342 | < 0.001 |
| Radiation dose (μGy·m2), mean ± SD | 12.3 ± 4.7 | 54.8 ± 13.6 | t = 11.579 | < 0.001 |
| Multivariate analysis | OR | 95%CI | - | P value |
| Risk factors for multiple adjustments | ||||
| Female sex | 2.13 | 1.25-3.64 | - | 0.005 |
| BMI ≥ 25 kg/m2 | 2.86 | 1.67-4.91 | - | < 0.001 |
| Traditional anatomical landmark technique | 6.52 | 3.78-11.25 | - | < 0.001 |
| Protective factor for reduced X-ray exposure | ||||
| Application of IC-ECG technique | 0.12 | 0.05-0.28 | - | < 0.001 |
- Citation: Xie GL, Heng J, Jia XF, Li Q, Chang R, Zhang N, Xie LL, Gao C. Image and intracavitary electrocardiogram-guided arm port placement in colorectal cancer: A retrospective comparative study. World J Gastrointest Surg 2025; 17(10): 109407
- URL: https://www.wjgnet.com/1948-9366/full/v17/i10/109407.htm
- DOI: https://dx.doi.org/10.4240/wjgs.v17.i10.109407