Table 5 Haemodynamic effects of ultrasonic cardiac output monitor-guided fluid resuscitation in the intervention group, mean ± SD
| Parameters | Baseline | Post-resuscitation | t-value | Cohen’s d | Mean difference | 95%CI | P value |
| SV (mL) | 29.8 ± 4.5 | 68.6 ± 9.7 | 14.82 | 2.96 | 38.8 | 33.2-44.4 | < 0.001 |
| CO (L/minute) | 3.0 ± 0.7 | 5.4 ± 1.0 | 12.00 | 2.40 | 2.4 | 1.9-2.9 | < 0.001 |
- Citation: Bo Y, Li HJ, Han ZZ, Tian LJ, Chen YF. Non-invasive haemodynamic monitoring to individualise fluid resuscitation in adult diabetic ketoacidosis: A randomized controlled pilot trial. World J Diabetes 2026; 17(8): 121563