Review
Copyright ©The Author(s) 2016.
World J Gastrointest Endosc. Jan 25, 2016; 8(2): 104-112
Published online Jan 25, 2016. doi: 10.4253/wjge.v8.i2.104
Table 2 Clinical details of case series on endoscopic ultrasound-guided biliary drainage due to surgically altered anatomy
Ref.EtiologyProcedure (technical success rate, %)Complications
Iwashita et al[28] (n = 7)Stone (n = 5) Stricture (n = 1) Malignant (n = 1)Stone removal, 100% Dilation, 100% Stent placement, 100% (SEMS)Minor: 28%
Itoi et al[29] (n = 14)Stone (n = 14)Single session clearance, 60% Overall clearance, 71.4%None