Copyright: ©Author(s) 2026.
World J Gastrointest Endosc. Mar 16, 2026; 18(3): 116646
Published online Mar 16, 2026. doi: 10.4253/wjge.v18.i3.116646
Published online Mar 16, 2026. doi: 10.4253/wjge.v18.i3.116646
Table 4 Specificity of complex loop during single person colonoscopy insertion
| Loop type | Time (seconds) | MID DELT. R MPF slope (%) | FLEX.CARP.R. L MPF slope (%) | FLEX.CARP.R. R MPF slope (%) | EXT.DIG. L RMS (μV) | EXT.DIG. R MPF slope (%) |
| No loop | 53.6 | 15.9 | 25.7 | 12.2 | 225.1 | 22.4 |
| “γ” loop | 68.6 | 2.6 | 10.1 | 12.5 | 228.5 | 13.4 |
| “α” loop | 112.0 | 21.3 | 33.0 | 15.9 | 289.1 | 19.6 |
| Reverse “α” loop | 81.9 | 31.4 | 35.7 | 10.4 | 316.3 | 37.0 |
| “N” loop | 80.1 | 15.0 | 7.3 | 24.4 | 347.2 | 27.0 |
| Complex loop | 87.6 | 38.4 | 36.1 | 26.5 | 370.6 | 31.8 |
- Citation: Wang RG, Wang YQ, Cao H. Bilateral upper limb surface electromyography analysis during single-operator colonoscopy: Implications for ergonomics and occupational health. World J Gastrointest Endosc 2026; 18(3): 116646
- URL: https://www.wjgnet.com/1948-5190/full/v18/i3/116646.htm
- DOI: https://dx.doi.org/10.4253/wjge.v18.i3.116646