Table 3 Representative primary studies of artificial intelligence-assisted endoscopic documentation and report generation
Ref.
System/input
Setting/sample
Clinical function
Design/comparator
Evaluation unit
Key findings
Validation/main limitation
Qu et al[18], 2020ISRGS; endoscopic images/video46987 images; prospective set: 5699 imagesSite/lesion recognition and structured report generationMulticenter development and prospective validationImage/patientOverall diagnostic accuracy: 88.41% multicenter; 89.65% prospectiveMulticenter data, but structured/template-based output
Dong et al[65], 2022EAIRS; real-time EGD video210198 development images; 161 prospective patientsAutomated photo-documentationInternal, external and prospective testing; system vs endoscopistsPatient/procedureLandmark capture accuracy 95.2%; completeness: 93.1% vs 88.8%; detected-lesion capture: 99% vs 98%Multicenter development; mainly image documentation rather than full narrative report
Yokota et al[67], 2022Voice Capture/speech input356 patients; 101 propensity-matched pairsSpeech-assisted structured reportingRetrospective propensity-matched comparison; voice recognition vs manual entryProcedureMedian report preparation time: 311 s vs 383 s, P = 0.009Single-center retrospective study
Zhang et al[19], 2023AI-EARS; EGD video/image252111 images for training, 62706 images, and 950 videos for testingAutomatic image capture, diagnosis and textual descriptionMultireader multicase randomized crossover; AI-EARS vs conventional reportingReport/procedureText completeness: 79.03% vs 51.86%; accuracy: 64.47% vs 42.81%; reporting time: 46.47 s vs 80.13 sRelatively small clinical crossover sample
Naito et al[20], 2025AR-C1; video/procedural events 40 endoscopic mucosal resection proceduresProcedure-event capture and report supportRetrospective clinical comparisonProcedure/reportReport generation time: 186.6 s vs 258.4 sSingle-center and single examiner
You et al[66], 2026AI gastric-lesion reporting system276 video clips; prospective clinical analysis: 100 patientsStructured lesion documentationProspective AI-assisted vs routine reportingLesion/reportOverall lesion-report completeness: 86.5% vs 75.11%, P = 0.001Prospective but single-center
Kawagoe et al[68], 2026EVAS voice recognition21 cases; 5 experienced endoscopistsVoice-assisted colonoscopy reportingPilot comparison; EVAS vs manual typingReportMean reporting time: 29 s vs 56 s; 46.3% reductionVery small pilot; recognition accuracy/system integration require further evaluation
Jiang et al[21], 2026Report-Angel; endoscopic images/videos + text20617 training image-text pairs; prospective internal n = 300 and external n = 300 cohortsMLLM-generated draft EGD reportsProspective internal and external clinical validation; expert review of generated draftsCase/report + lesionClinically acceptable draft reports: 79.3% internal, 83.3% external; case completeness 88.51%, accuracy 78.93%Strongest current prospective MLLM evidence; generated drafts still require clinician review
Massimi et al[71], 2026Gemini 2.5 Pro; complete EGD video5 full-length EGD videosMLLM video analysis and report generationRetrospective paired pilot; clean video vs same video with CAD overlayReport/eventAdequate completeness: 56% vs 48%; landmark accuracy: 0.55 vs 0.33Extremely small pilot; authors concluded performance was inadequate for clinical EGD reporting