Table 4 Multivariate logistic regression analysis of predictors of optimal histopathological specimen according to European Association for the Study of Liver criteria (adjusted for age and gender)
| Variable | Adjusted odds ratio | 95% confidence intervals | P value |
| Use of FNB needle | 19.9 | 4.2-94.2 | < 0.0001 |
| Use of wet heparin suction | 7.8 | 2.1-29.1 | 0.002 |
| Performing > 2 passes | 0.10 | 0.02-0.47 | 0.003 |
- Citation: Alali AA, Ali N, Hashim A, Alhaqqan D, Aljasser W, Almudaires A, Bastaki S, Alhashmi A, Altaleb A. Feasibility and safety of endoscopic ultrasound-guided liver biopsy to diagnose parenchymal liver disease: A multi-centre retrospective cohort study. World J Gastrointest Endosc 2025; 17(12): 112485