BPG is committed to discovery and dissemination of knowledge
Review
©The Author(s) 2025.
World J Gastrointest Endosc. Dec 16, 2025; 17(12): 111782
Published online Dec 16, 2025. doi: 10.4253/wjge.v17.i12.111782
Table 2 Techniques of the clip and line/Loop strategy for closure
Technique
Auxiliary instruments
Procedure details
Pros
Cons
Loop-clip closure Loop–clip: Consists of a loop of nylon string attached to a metallic clipLoop-clip device is fixed to the edge of the defect at the mid of distal side. Then, another TTSC is passed to hook and pull the loop to fix on the proximal defect margin. Afterwards, the complete closure is achieved by the use of regular TTSCSuitable for large defects. Applicable for all GI segments. No need for a double-channel scope. No need for scope withdrawal and reinsertionNeed for a special device
Clip-band closure Clip-band device: 3 interconnected elastic silicon bands (two 3.3 mm rings and one 15 mm ring) preloaded on the clipThe clip-band device is fixed to the edge of the defect at the distal side. Then, another TTSC is passed to hook and pull the band to fix on the proximal defect margin. Afterwards, the same clip-band sequence or standard TTSC can be applied to achieve complete closure
Endoscopic sliding closureRing-shaped surgical thread (8, 10 and 12 mm diameter)The ring thread is clipped at two points across the maximum diameter of the defect margins. A third clip then grasps one side of the ring thread and then draws across the opposite end to bring the clips and defect margins closure. The process can be repeated at 2-3 sites, depending on size. Subsequently, complete closure can be achieved by the standard TTSC
Clip-line closure Long nylon line tied on the arm of the endoclipEndoclip (with attached nylon line on one arm) is fixed to healthy mucosa 5 mm from the defect margin on one side. The other side of the defect margin, along with the line, is then anchored by another endoclip. Both the defect margins, along with clips, are approximated by gentle pulling of the line. Further, additional clips with/without lines are placed to achieve complete closure
Ring/king closure Detachable endoloopThe apex of the detachable endoloop is fixed to one edge of the defect using an endoclip. With the help of multiple clips, the loop is garlanded to the defect margins. The loop is tightened to close the defect in a purse-string manner
ROLMMuscle layer grasping clips, a reopenable clip, and nylon lineReopenable clip with a nylon line fixed on it clips the normal mucosa and muscle layer of the distal side of the defect margin. The end of the line exiting through the accessory channel of the endoscope is passed through the hole in one tooth of the second reopenable clip. This second clip with the line (ROLM) is placed on the opposite side of the defect, and the muscle layer is being grasped by the tooth through which the line has been passed. Repeating ROLM gradually closes the defect from the distal to the proximal sideSuitable for thick-walled sections of GI tract defects like gastric and rectal defects (risk of dead space with conventional closure methods). Teeth of the reopenable clips through which nylon line passes are continuously fixed by the line, preventing the clips from being buried into the muscle layer sideNeed for muscle layer grasping clips, reopenable clips, and a nylon line