©The Author(s) 2019.
World J Gastrointest Endosc. Mar 16, 2019; 11(3): 193-208
Published online Mar 16, 2019. doi: 10.4253/wjge.v11.i3.193
Published online Mar 16, 2019. doi: 10.4253/wjge.v11.i3.193
Table 1 Commercially available colorectal stents
| Manufacturer and model | Material | Delivery system | Diameter (mm) | Flare | Flare diameter (mm) | Length (mm) | Covered/uncovered |
| Boston Scientific | |||||||
| Wallstent Colonic1 | Nitinol | TTS | 22, 25 | 1 | 27, 30 | 60, 90, 120 | Uncovered |
| Wallstent Endoprothesis1 | Stainless steel | TTS | 20, 22 | 0 | – | 60, 90, 120 | Uncovered |
| Ultraflex Precision Colonic1 | Nitinol | OTW | 25 | 1 | 30 | 57, 87, 117 | Uncovered |
| Micro-Tech Europe | OTW | 30 | 0 | – | 75, 88, 112, 123, 136 | Uncovered/fully covered | |
| Micro-Tech Europe Colon and Rectum stent | Nitinol | OTW | 20, 30 | 2 | 26, 36 | 60, 80, 100 | Uncovered/partially covered |
| Leufen Medical GmbH | TTS | 25 | 2 | 30 | 80, 100, 120 | Uncovered | |
| Colon Rectum Stent | Nitinol | OTW | 25, 30 | 2 | 30, 36 | 80, 100 | Uncovered/partially covered |
| TTS | 25 | 2 | 30 | 80, 100 | Uncovered | ||
| Cook | |||||||
| Evolution Colonic1 | Nitinol | TTS | 25 | 2 | 30 | 60, 80,100 | Uncovered |
| MI Tech | |||||||
| Hanarostent Colon/Rectum1 | Nitinol | TTS | 22, 24 | 2 | 26, 28 | 80, 110, 140, 170 | Uncovered |
| TTS/OTW | 20, 24 | 2 | 26, 32 | 60, 90, 100, 120, 130, 160 | Fully covered | ||
| OTW | 24 | 2 | 32 | 50,80,110,150 | Fully Covered | ||
| Choostent Colon/Rectum | Nitinol | OTW | 22,24 | 2 | 30, 32 | 100, 180 | Fully covered |
| EndoChoice | OTW | 22,24 | 2 | 30, 32 | 80, 120 | Fully covered | |
| Bonastent | Nitinol | TTS | 22, 24, 26 | 0 | – | 60, 80, 100 | Uncovered/partially covered |
| Taewoong Medical | |||||||
| Niti-S Enteral Colonic D-type1 | Nitinol | TTS | 18, 20, 22, 24, 26, 28 | 0 | – | 60, 80, 100, 120 | Uncovered |
| Niti-S Enteral Colonic S-type1 | Nitinol | TTS | 20, 22 | 2 | 28, 30 | 60, 80, 100, 120 | Fully/partially covered |
| OTW | 22, 24, 26, 28 | 2 | 30, 32, 34 | 60, 80, 100, 120 | Fully/partially covered | ||
| Self expandable Stent | |||||||
| Braile Endomédica | Nitinol | TTS | 26 | 0 | - | 70, 100, 130 | Partially covered |
- Citation: Ribeiro IB, de Moura DTH, Thompson CC, de Moura EGH. Acute abdominal obstruction: Colon stent or emergency surgery? An evidence-based review. World J Gastrointest Endosc 2019; 11(3): 193-208
- URL: https://www.wjgnet.com/1948-5190/full/v11/i3/193.htm
- DOI: https://dx.doi.org/10.4253/wjge.v11.i3.193