BPG is committed to discovery and dissemination of knowledge
Cited by in F6Publishing
For: van den Boomen M, Manhard MK, Snel GJH, Han S, Emblem KE, Slart RHJA, Sosnovik DE, Catana C, Rosen BR, Prakken NHJ, Nguyen CT, Borra RJH, Setsompop K. Blood Oxygen Level-Dependent MRI of the Myocardium with Multiecho Gradient-Echo Spin-Echo Imaging. Radiology 2020;294:538-45. [PMID: 31961241 DOI: 10.1148/radiol.2020191845] [Cited by in Crossref: 6] [Cited by in F6Publishing: 6] [Article Influence: 3.0] [Reference Citation Analysis]
Number Citing Articles
1 Iannino N, Fischer K, Friedrich M, Hafyane T, Mongeon FP, White M. Myocardial Vascular Function Assessed by Dynamic Oxygenation-sensitive Cardiac Magnetic Resonance Imaging Long-term Following Cardiac Transplantation. Transplantation 2021;105:1347-55. [PMID: 32804801 DOI: 10.1097/TP.0000000000003419] [Cited by in Crossref: 3] [Cited by in F6Publishing: 2] [Article Influence: 3.0] [Reference Citation Analysis]
2 Vu C, Chai Y, Coloigner J, Nederveen AJ, Borzage M, Bush A, Wood JC. Quantitative perfusion mapping with induced transient hypoxia using BOLD MRI. Magn Reson Med 2021;85:168-81. [PMID: 32767413 DOI: 10.1002/mrm.28422] [Cited by in Crossref: 1] [Cited by in F6Publishing: 2] [Article Influence: 0.5] [Reference Citation Analysis]
3 Emrich T, Halfmann M, Schoepf UJ, Kreitner KF. CMR for myocardial characterization in ischemic heart disease: state-of-the-art and future developments. Eur Radiol Exp 2021;5:14. [PMID: 33763757 DOI: 10.1186/s41747-021-00208-2] [Cited by in Crossref: 2] [Cited by in F6Publishing: 2] [Article Influence: 2.0] [Reference Citation Analysis]
4 Herrmann CJJ, Els A, Boehmert L, Periquito J, Eigentler TW, Millward JM, Waiczies S, Kuchling J, Paul F, Niendorf T. Simultaneous T2 and T 2 mapping of multiple sclerosis lesions with radial RARE-EPI. Magn Reson Med 2021;86:1383-402. [PMID: 33951214 DOI: 10.1002/mrm.28811] [Reference Citation Analysis]
5 Guensch DP, Michel MC, Huettenmoser SP, Jung B, Gulac P, Segiser A, Longnus SL, Fischer K. The blood oxygen level dependent (BOLD) effect of in-vitro myoglobin and hemoglobin. Sci Rep 2021;11:11464. [PMID: 34075096 DOI: 10.1038/s41598-021-90908-x] [Cited by in Crossref: 1] [Cited by in F6Publishing: 2] [Article Influence: 1.0] [Reference Citation Analysis]
6 Fischer K, Neuenschwander MD, Jung C, Hurni S, Winkler BM, Huettenmoser SP, Jung B, Vogt AP, Eberle B, Guensch DP. Assessment of Myocardial Function During Blood Pressure Manipulations Using Feature Tracking Cardiovascular Magnetic Resonance. Front Cardiovasc Med 2021;8:743849. [PMID: 34712713 DOI: 10.3389/fcvm.2021.743849] [Reference Citation Analysis]