BPG is committed to discovery and dissemination of knowledge
Cited by in F6Publishing
For: Chuong M, Badiyan SN, Yam M, Li Z, Langen K, Regine W, Morris C, Snider J 3rd, Mehta M, Huh S, Rutenberg M, Nichols RC. Pencil beam scanning versus passively scattered proton therapy for unresectable pancreatic cancer. J Gastrointest Oncol 2018;9:687-93. [PMID: 30151265 DOI: 10.21037/jgo.2018.03.14] [Cited by in Crossref: 13] [Cited by in F6Publishing: 12] [Article Influence: 4.3] [Reference Citation Analysis]
Number Citing Articles
1 Dell'Oro M, Short M, Wilson P, Bezak E. Clinical Limitations of Photon, Proton and Carbon Ion Therapy for Pancreatic Cancer. Cancers (Basel) 2020;12:E163. [PMID: 31936565 DOI: 10.3390/cancers12010163] [Cited by in Crossref: 5] [Cited by in F6Publishing: 5] [Article Influence: 5.0] [Reference Citation Analysis]
2 Kubeš J, Haas A, Vondráček V, Andrlík M, Navrátil M, Sláviková S, Vítek P, Dědečková K, Prausová J, Ondrová B, Vinakurau Š, Grebenyuk A, Doležal T, Velacková B, Rosina J. Ultrahypofractionated Proton Radiation Therapy in the Treatment of Low and Intermediate-Risk Prostate Cancer-5-Year Outcomes. Int J Radiat Oncol Biol Phys 2021;110:1090-7. [PMID: 33587990 DOI: 10.1016/j.ijrobp.2021.02.014] [Cited by in Crossref: 1] [Cited by in F6Publishing: 1] [Article Influence: 1.0] [Reference Citation Analysis]
3 Raturi VP, Hojo H, Hotta K, Baba H, Takahashi R, Rachi T, Nakamura N, Zenda S, Motegi A, Tachibana H, Ariji T, Motegi K, Nakamura M, Okumura M, Hirano Y, Akimoto T. Radiobiological model-based approach to determine the potential of dose-escalated robust intensity-modulated proton radiotherapy in reducing gastrointestinal toxicity in the treatment of locally advanced unresectable pancreatic cancer of the head. Radiat Oncol 2020;15:157. [PMID: 32571379 DOI: 10.1186/s13014-020-01592-6] [Reference Citation Analysis]
4 Zou W, Diffenderfer ES, Ota K, Boisseau P, Kim MM, Cai Y, Avery SM, Carlson DJ, Wiersma RD, Lin A, Koumenis C, Cengel KA, Metz JM, Dong L, Teo BK. Characterization of a high-resolution 2D transmission ion chamber for independent validation of proton pencil beam scanning of conventional and FLASH dose delivery. Med Phys 2021;48:3948-57. [PMID: 33843065 DOI: 10.1002/mp.14882] [Cited by in F6Publishing: 1] [Reference Citation Analysis]
5 Lehrer EJ, Prabhu AV, Sindhu KK, Lazarev S, Ruiz-Garcia H, Peterson JL, Beltran C, Furutani K, Schlesinger D, Sheehan JP, Trifiletti DM. Proton and Heavy Particle Intracranial Radiosurgery. Biomedicines 2021;9:31. [PMID: 33401613 DOI: 10.3390/biomedicines9010031] [Cited by in Crossref: 3] [Cited by in F6Publishing: 3] [Article Influence: 3.0] [Reference Citation Analysis]
6 Chalise AR, Chi Y, Lai Y, Shao Y, Jin M. Carbon-11 and Carbon-12 beam range verifications through prompt gamma and annihilation gamma measurements: Monte Carlo simulations. Biomed Phys Eng Express 2020;6:065013. [PMID: 34040798 DOI: 10.1088/2057-1976/abb8b6] [Reference Citation Analysis]
7 Stefanowicz S, Wlodarczyk W, Frosch S, Zschaeck S, Troost EGC. Dose-escalated simultaneously integrated boost photon or proton therapy in pancreatic cancer in an in-silico study: Gastrointestinal organs remain critical. Clin Transl Radiat Oncol 2021;27:24-31. [PMID: 33392399 DOI: 10.1016/j.ctro.2020.12.001] [Reference Citation Analysis]
8 Lecornu M, Lesueur P, Salleron J, Balosso J, Stefan D, Kao W, Plouhinec T, Vela A, Dutheil P, Bouter J, Marty PA, Thariat J, Quintyn JC. Prospective Assessment of Early Proton Therapy-Induced Optic Neuropathy in Patients With Intracranial, Orbital or Sinonasal Tumors: Impact of A Standardized Ophthalmological Follow Up. Front Oncol 2021;11:673886. [PMID: 34211847 DOI: 10.3389/fonc.2021.673886] [Reference Citation Analysis]
9 Rutenberg MS, Nichols RC. Proton beam radiotherapy for pancreas cancer. J Gastrointest Oncol 2020;11:166-75. [PMID: 32175120 DOI: 10.21037/jgo.2019.03.02] [Cited by in Crossref: 5] [Cited by in F6Publishing: 4] [Article Influence: 5.0] [Reference Citation Analysis]
10 Rana S, Bennouna J, Gutierrez AN, Rosenfeld AB. Impact of magnetic field regulation in conjunction with the volumetric repainting technique on the spot positions and beam range in pencil beam scanning proton therapy. J Appl Clin Med Phys 2020;21:124-31. [PMID: 33058380 DOI: 10.1002/acm2.13045] [Cited by in Crossref: 3] [Cited by in F6Publishing: 3] [Article Influence: 3.0] [Reference Citation Analysis]
11 Zou W, Diffenderfer ES, Cengel KA, Kim MM, Avery S, Konzer J, Cai Y, Boisseu P, Ota K, Yin L, Wiersma R, Carlson DJ, Fan Y, Busch TM, Koumenis C, Lin A, Metz JM, Teo BK, Dong L. Current delivery limitations of proton PBS for FLASH. Radiotherapy and Oncology 2021;155:212-8. [DOI: 10.1016/j.radonc.2020.11.002] [Cited by in Crossref: 5] [Cited by in F6Publishing: 5] [Article Influence: 5.0] [Reference Citation Analysis]
12 Matsumoto Y, Fukumitsu N, Ishikawa H, Nakai K, Sakurai H. A Critical Review of Radiation Therapy: From Particle Beam Therapy (Proton, Carbon, and BNCT) to Beyond. J Pers Med 2021;11:825. [PMID: 34442469 DOI: 10.3390/jpm11080825] [Reference Citation Analysis]