BPG is committed to discovery and dissemination of knowledge
Cited by in F6Publishing
For: Levernæs MCS, Broughton MN, Reubsaet L, Halvorsen TG. To elute or not to elute in immunocapture bottom-up LC–MS. Journal of Chromatography B 2017;1055-1056:51-60. [DOI: 10.1016/j.jchromb.2017.03.044] [Cited by in Crossref: 7] [Cited by in F6Publishing: 7] [Article Influence: 1.4] [Reference Citation Analysis]
Number Citing Articles
1 Skjærvø Ø, Halvorsen TG, Reubsaet L. Pre-lab proteolysis for dried serum spots – a paper-based sampling concept targeting low abundant biomarkers. Anal Methods 2020;12:97-103. [DOI: 10.1039/c9ay01976f] [Cited by in Crossref: 3] [Article Influence: 1.5] [Reference Citation Analysis]
2 Sugimoto H, Wei D, Dong L, Ghosh D, Chen S, Qian MG. Perspectives on potentiating immunocapture-LC-MS for the bioanalysis of biotherapeutics and biomarkers. Bioanalysis 2018;10:1679-90. [PMID: 30371100 DOI: 10.4155/bio-2018-0205] [Cited by in Crossref: 5] [Cited by in F6Publishing: 4] [Article Influence: 1.3] [Reference Citation Analysis]
3 Al Matari A, Goumenou A, Combès A, Fournier T, Pichon V, Delaunay N. Identification and semi-relative quantification of intact glycoforms of human chorionic gonadotropin alpha and beta subunits by nano liquid chromatography-Orbitrap mass spectrometry. J Chromatogr A 2021;1640:461945. [PMID: 33556683 DOI: 10.1016/j.chroma.2021.461945] [Reference Citation Analysis]
4 Neubert H, Shuford CM, Olah TV, Garofolo F, Schultz GA, Jones BR, Amaravadi L, Laterza OF, Xu K, Ackermann BL. Protein Biomarker Quantification by Immunoaffinity Liquid Chromatography–Tandem Mass Spectrometry: Current State and Future Vision. Clinical Chemistry 2020;66:282-301. [DOI: 10.1093/clinchem/hvz022] [Cited by in Crossref: 19] [Cited by in F6Publishing: 22] [Article Influence: 9.5] [Reference Citation Analysis]
5 Kvivik I, Jonsson G, Omdal R, Brede C. Sample Preparation Strategies for Antibody-Free Quantitative Analysis of High Mobility Group Box 1 Protein. Pharmaceuticals (Basel) 2021;14:537. [PMID: 34205112 DOI: 10.3390/ph14060537] [Reference Citation Analysis]
6 Klont F, Kwiatkowski M, Faiz A, van den Bosch T, Pouwels SD, Dekker FJ, Ten Hacken NHT, Horvatovich P, Bischoff R. Adsorptive Microtiter Plates As Solid Supports in Affinity Purification Workflows. J Proteome Res 2021;20:5218-21. [PMID: 34669399 DOI: 10.1021/acs.jproteome.1c00623] [Reference Citation Analysis]
7 Levernæs MCS, Farhat B, Oulie I, Abdullah SS, Paus E, Reubsaet L, Halvorsen TG. Immunocapture sample clean-up in determination of low abundant protein biomarkers – a feasibility study of peptide capture by anti-protein antibodies. RSC Adv 2019;9:34902-11. [DOI: 10.1039/c9ra05071j] [Cited by in Crossref: 7] [Article Influence: 2.3] [Reference Citation Analysis]