Enteroscope device | ||||
Entire cohort | Retrograde SBE1 | Retrograde TTSE2 | ||
Number of procedures | 81 | 54 | 27 | |
Mean (SD) | Mean (SD) | Mean (SD) | P value3 | |
Duration of procedure | 86.2 (34.2) | 91.9 (34.2) | 70.5 (30.7) | 0.04 |
Depth of the scope insertion | 82.1 (64.1) | 92.5 (70.0) | 64.6 (49.0) | 0.08 |
Successful procedure with diagnostic yield, n (%) | n = 64 | n = 41 | n = 23 | 0.39 |
Normal | 43 (67.2) | 26 (63.4) | 17 (73.9) | |
Positive finding | 21 (32.8) | 15 (36.6) | 6 (26.1) | |
Intervention performed, n (%) | 0.38 | |||
No | 65 (80.3) | 45 (83.3) | 20 (74.1) | |
Yes | 16 (19.8) | 9 (16.7) | 7 (25.9) | |
Failed (2011-2018), n (%) | 17 (21.0) | 13 (24.1) | 4 (14.8) | 0.33 |
Terminal ileum not intubated | 9 (11.1) | 8 (14.8) | 1 (3.7) | |
Insertion < 20 cm | 8 (9.9) | 5 (9.3) | 3 (11.1) | |
Years | Failed/procedure | Failed/procedure | Failed/procedure | |
2011-2012 | 5/14 | 5/14 | - | |
2013-2014 | 4/27 | 4/22 | 0/5 | |
2015-2016 | 6/26 | 3/11 | 3/15 | |
2017-2018 | 2/14 | 1/7 | 1/7 |
- Citation: Jia Y, Michael M, Bashashati M, Elhanafi S, Dodoo C, Dwivedi AK, Carrion AF, Othman MO, Zuckerman MJ. Evaluation of the diagnostic and therapeutic utility of retrograde through-the-scope balloon enteroscopy and single-balloon enteroscopy. World J Gastrointest Endosc 2020; 12(11): 459-468
- URL: https://www.wjgnet.com/1948-5190/full/v12/i11/459.htm
- DOI: https://dx.doi.org/10.4253/wjge.v12.i11.459