BPG is committed to discovery and dissemination of knowledge
Cited by in F6Publishing
For: Zhao HQ, Nikanorov A, Virmani R, Jones R, Pacheco E, Schwartz LB. Late stent expansion and neointimal proliferation of oversized Nitinol stents in peripheral arteries. Cardiovasc Intervent Radiol. 2009;32:720-726. [PMID: 19484292 DOI: 10.1007/s00270-009-9601-z] [Cited by in Crossref: 75] [Cited by in F6Publishing: 43] [Article Influence: 6.3] [Reference Citation Analysis]
Number Citing Articles
1 Jafary-Zadeh M, Praveen Kumar G, Branicio PS, Seifi M, Lewandowski JJ, Cui F. A Critical Review on Metallic Glasses as Structural Materials for Cardiovascular Stent Applications. J Funct Biomater 2018;9:E19. [PMID: 29495521 DOI: 10.3390/jfb9010019] [Cited by in Crossref: 33] [Cited by in F6Publishing: 6] [Article Influence: 11.0] [Reference Citation Analysis]
2 Deloose K, Bosiers M, Peeters P, Verbist J, Maene L, Beelen R, Keirse K, Hendriks J, Lauwers P, Wauters J, Verschueren M. Combining the Passeo-18 Lux Drug-Coated Balloon and the Pulsar-18 Bare Metal Stent: 12- and 24-Month Outcomes of the BIOLUX 4EVER Investigator-Initiated Trial. J Endovasc Ther 2020;27:936-45. [PMID: 32873131 DOI: 10.1177/1526602820952413] [Reference Citation Analysis]
3 Miki K, Fujii K, Shibuya M, Fukunaga M, Imanaka T, Kawai K, Tamaru H, Sumiyoshi A, Nishimura M, Horimatsu T, Saita T, Yoshihara N, Kimura T, Honda Y, Fitzgerald PJ, Masuyama T, Ishihara M. Impact of stent diameter on vascular response after self-expanding paclitaxel-eluting stent implantation in the superficial femoral artery. J Cardiol 2017;70:346-52. [PMID: 28254383 DOI: 10.1016/j.jjcc.2016.12.011] [Cited by in Crossref: 6] [Cited by in F6Publishing: 4] [Article Influence: 1.5] [Reference Citation Analysis]
4 Zhao HQ, Jayasinghe D, Hossainy S, Schwartz LB. A theoretical model to characterize the drug release behavior of drug-eluting stents with durable polymer matrix coating. J Biomed Mater Res 2012;100A:120-4. [DOI: 10.1002/jbm.a.33246] [Cited by in Crossref: 18] [Cited by in F6Publishing: 10] [Article Influence: 1.8] [Reference Citation Analysis]
5 Sequeira A, Abreo K. The Structure and Function of Endovascular Stents: A Primer for the Interventional Nephrologist: Structure and Function of Endovascular Stents. Semin Dial 2014;27:E10-20. [DOI: 10.1111/sdi.12075] [Cited by in Crossref: 4] [Cited by in F6Publishing: 1] [Article Influence: 0.5] [Reference Citation Analysis]
6 Ishihara T, Sotomi Y, Tsujimura T, Iida O, Kobayashi T, Hamanaka Y, Omatsu T, Sakata Y, Higuchi Y, Mano T. Impact of diabetes mellitus on the early-phase arterial healing after drug-eluting stent implantation. Cardiovasc Diabetol 2020;19:203. [PMID: 33267863 DOI: 10.1186/s12933-020-01173-7] [Cited by in Crossref: 1] [Cited by in F6Publishing: 1] [Article Influence: 1.0] [Reference Citation Analysis]
7 Kim J, Yoon CJ, Seong N, Lee H, Kim Y. Spontaneous Dissection of Superior Mesenteric Artery: Long-Term Outcome of Stent Placement. Journal of Vascular and Interventional Radiology 2017;28:1722-6. [DOI: 10.1016/j.jvir.2017.05.022] [Cited by in Crossref: 9] [Cited by in F6Publishing: 4] [Article Influence: 2.3] [Reference Citation Analysis]
8 Wressnegger A, Kaider A, Funovics MA. Self-expanding nitinol stents of high versus low chronic outward force in de novo femoropopliteal occlusive arterial lesions (BIOFLEX-COF trial): study protocol for a randomized controlled trial. Trials 2017;18:594. [PMID: 29237489 DOI: 10.1186/s13063-017-2338-0] [Cited by in Crossref: 5] [Cited by in F6Publishing: 4] [Article Influence: 1.3] [Reference Citation Analysis]
9 Ohki T, Kichikawa K, Yokoi H, Iida O, Yamaoka T, Maeda K, Kanaoka Y. Long-term results of the Japanese multicenter Viabahn trial of heparin bonded endovascular stent grafts for long and complex lesions in the superficial femoral artery. J Vasc Surg 2021:S0741-5214(21)01011-9. [PMID: 34182032 DOI: 10.1016/j.jvs.2021.05.056] [Reference Citation Analysis]
10 Müller-Hülsbeck S, Keirse K, Zeller T, Schroë H, Diaz-Cartelle J. Long-Term Results from the MAJESTIC Trial of the Eluvia Paclitaxel-Eluting Stent for Femoropopliteal Treatment: 3-Year Follow-up. Cardiovasc Intervent Radiol 2017;40:1832-8. [PMID: 28948322 DOI: 10.1007/s00270-017-1771-5] [Cited by in Crossref: 36] [Cited by in F6Publishing: 16] [Article Influence: 9.0] [Reference Citation Analysis]
11 Gökgöl C, Diehm N, Nezami FR, Büchler P. Nitinol Stent Oversizing in Patients Undergoing Popliteal Artery Revascularization: A Finite Element Study. Ann Biomed Eng 2015;43:2868-80. [PMID: 26101031 DOI: 10.1007/s10439-015-1358-8] [Cited by in Crossref: 16] [Cited by in F6Publishing: 11] [Article Influence: 2.7] [Reference Citation Analysis]
12 Albaghdadi MS, Yang J, Brown JH, Mansukhani NA, Ameer GA, Kibbe MR. A Tailorable In-Situ Light-Activated Biodegradable Vascular Scaffold. Adv Mater Technol 2017;2:1600243. [PMID: 29578542 DOI: 10.1002/admt.201600243] [Cited by in Crossref: 2] [Cited by in F6Publishing: 2] [Article Influence: 0.5] [Reference Citation Analysis]
13 Grotti S, Liistro F, Angioli P, Ducci K, Falsini G, Porto I, Ricci L, Ventoruzzo G, Turini F, Bellandi G, Bolognese L. Paclitaxel-Eluting Balloon vs Standard Angioplasty to Reduce Restenosis in Diabetic Patients With In-Stent Restenosis of the Superficial Femoral and Proximal Popliteal Arteries: Three-Year Results of the DEBATE-ISR Study. J Endovasc Ther 2016;23:52-7. [PMID: 26511896 DOI: 10.1177/1526602815614555] [Cited by in Crossref: 46] [Cited by in F6Publishing: 28] [Article Influence: 7.7] [Reference Citation Analysis]
14 Hsu MC, Weber CN, Stavropoulos SW, Clark TW, Trerotola SO, Shlansky-Goldberg RD, Soulen MC, Nadolski GJ. Passive expansion of sub-maximally dilated transjugular intrahepatic portosystemic shunts and assessment of clinical outcomes. World J Hepatol 2017;9:603-12. [PMID: 28515846 DOI: 10.4254/wjh.v9.i12.603] [Cited by in Crossref: 3] [Cited by in F6Publishing: 3] [Article Influence: 0.8] [Reference Citation Analysis]
15 Meoli A, Dordoni E, Petrini L, Migliavacca F, Dubini G, Pennati G. Computational Modelling of In Vitro Set-Ups for Peripheral Self-Expanding Nitinol Stents: The Importance of Stent–Wall Interaction in the Assessment of the Fatigue Resistance. Cardiovasc Eng Tech 2013;4:474-84. [DOI: 10.1007/s13239-013-0164-4] [Cited by in Crossref: 12] [Cited by in F6Publishing: 5] [Article Influence: 1.5] [Reference Citation Analysis]
16 Meoli A, Dordoni E, Petrini L, Migliavacca F, Dubini G, Pennati G. Computational Study of Axial Fatigue for Peripheral Nitinol Stents. J of Materi Eng and Perform 2014;23:2606-13. [DOI: 10.1007/s11665-014-0965-0] [Cited by in Crossref: 10] [Cited by in F6Publishing: 3] [Article Influence: 1.4] [Reference Citation Analysis]
17 Li Z, Zhao R, Fang X, Huang Q, Liu J. Recombinant human SDF-1α administration accelerates aneurysm neck reendothelialization in rabbit saccular aneurysm after flow diverter treatment. Acta Biochimica et Biophysica Sinica 2017;49:246-53. [DOI: 10.1093/abbs/gmx001] [Cited by in Crossref: 7] [Cited by in F6Publishing: 7] [Article Influence: 1.8] [Reference Citation Analysis]
18 Saguner AM, Traupe T, Räber L, Hess N, Banz Y, Saguner AR, Diehm N, Hess OM. Oversizing and restenosis with self-expanding stents in iliofemoral arteries. Cardiovasc Intervent Radiol 2012;35:906-13. [PMID: 22006026 DOI: 10.1007/s00270-011-0275-y] [Cited by in Crossref: 24] [Cited by in F6Publishing: 15] [Article Influence: 2.4] [Reference Citation Analysis]
19 Torii S, Kolodgie FD, Virmani R, Finn AV. IN.PACT™ Admiral™ drug-coated balloons in peripheral artery disease: current perspectives. Med Devices (Auckl) 2019;12:53-64. [PMID: 30858737 DOI: 10.2147/MDER.S165620] [Cited by in Crossref: 2] [Cited by in F6Publishing: 2] [Article Influence: 1.0] [Reference Citation Analysis]
20 Zhao S, Gu L, Froemming SR. Finite Element Analysis of the Implantation of a Self-Expanding Stent: Impact of Lesion Calcification. Journal of Medical Devices 2012;6:021001. [DOI: 10.1115/1.4006357] [Cited by in Crossref: 13] [Cited by in F6Publishing: 5] [Article Influence: 1.4] [Reference Citation Analysis]
21 Sun J, Sun K, Bai K, Chen S, Zhao F, Wang F, Hong N, Hu H. Oversized composite braided biodegradable stents with post-dilatation for pediatric applications: mid-term results of a porcine study. Biomater Sci 2020;8:5183-95. [PMID: 32840505 DOI: 10.1039/d0bm00567c] [Cited by in Crossref: 4] [Cited by in F6Publishing: 2] [Article Influence: 4.0] [Reference Citation Analysis]
22 Shishehbor MH, Jaff MR. Percutaneous Therapies for Peripheral Artery Disease. Circulation 2016;134:2008-27. [PMID: 27956404 DOI: 10.1161/CIRCULATIONAHA.116.022546] [Cited by in Crossref: 46] [Cited by in F6Publishing: 9] [Article Influence: 11.5] [Reference Citation Analysis]
23 Myint M, Schouten O, Bourke V, Thomas SD, Lennox AF, Varcoe RL. A Real-World Experience With the Supera Interwoven Nitinol Stent in Femoropopliteal Arteries: Midterm Patency Results and Failure Analysis. J Endovasc Ther 2016;23:433-41. [DOI: 10.1177/1526602816639543] [Cited by in Crossref: 19] [Cited by in F6Publishing: 9] [Article Influence: 3.8] [Reference Citation Analysis]
24 Hiramori S, Soga Y, Iida O, Suzuki K, Hirano K, Kawasaki D, Shintani Y, Ando K. Relationship between clinical outcomes and vessel size in endovascular therapy for femoropopliteal lesions. Journal of Vascular Surgery 2017;65:1690-7. [DOI: 10.1016/j.jvs.2016.12.128] [Cited by in Crossref: 8] [Cited by in F6Publishing: 4] [Article Influence: 2.0] [Reference Citation Analysis]
25 Ishihara T, Iida O, Shiraki T, Fujita M, Inoue K, Uematsu M. Arterial repair after bare-metal stent implantation in peripheral arteries is delayed compared to that in coronary arteries: A case report of pathological evaluation. J Cardiol Cases 2016;14:74-7. [PMID: 30546670 DOI: 10.1016/j.jccase.2016.03.021] [Cited by in Crossref: 4] [Cited by in F6Publishing: 2] [Article Influence: 0.8] [Reference Citation Analysis]
26 Zhao S, Gu L, Froemming SR. Performance of Self-Expanding Nitinol Stent in a Curved Artery: Impact of Stent Length and Deployment Orientation. Journal of Biomechanical Engineering 2012;134:071007. [DOI: 10.1115/1.4007095] [Cited by in Crossref: 19] [Cited by in F6Publishing: 8] [Article Influence: 2.1] [Reference Citation Analysis]
27 Cho H, Nango M, Sakai Y, Sohgawa E, Kageyama K, Hamamoto S, Kitayama T, Yamamoto A, Miki Y. Neointimal hyperplasia after stent placement across size-discrepant vessels in an animal study. Jpn J Radiol 2014;32:340-6. [PMID: 24715330 DOI: 10.1007/s11604-014-0311-3] [Cited by in Crossref: 9] [Cited by in F6Publishing: 4] [Article Influence: 1.3] [Reference Citation Analysis]
28 Early M, Kelly DJ. The consequences of the mechanical environment of peripheral arteries for nitinol stenting. Med Biol Eng Comput 2011;49:1279-88. [PMID: 21833628 DOI: 10.1007/s11517-011-0815-2] [Cited by in Crossref: 23] [Cited by in F6Publishing: 17] [Article Influence: 2.3] [Reference Citation Analysis]
29 Sakaoka A, Souba J, Rousselle SD, Matsuda T, Tellez A, Hagiwara H, Nagano K, Tasaki M. Different Vascular Responses to a Bare Nitinol Stent in Porcine Femoral and Femoropopliteal Arteries. Toxicol Pathol 2019;47:408-17. [DOI: 10.1177/0192623318800726] [Cited by in Crossref: 3] [Cited by in F6Publishing: 1] [Article Influence: 1.0] [Reference Citation Analysis]
30 Gombert A. Why We Should Support Basic Research in the Field of Vascular Surgery. Eur J Vasc Endovasc Surg 2021;61:656. [PMID: 33358099 DOI: 10.1016/j.ejvs.2020.11.042] [Reference Citation Analysis]
31 Ohki T, Kichikawa K, Yokoi H, Uematsu M, Yamaoka T, Maeda K, Kanaoka Y. Outcomes of the Japanese multicenter Viabahn trial of endovascular stent grafting for superficial femoral artery lesions. Journal of Vascular Surgery 2017;66:130-142.e1. [DOI: 10.1016/j.jvs.2017.01.065] [Cited by in Crossref: 39] [Cited by in F6Publishing: 17] [Article Influence: 9.8] [Reference Citation Analysis]
32 Li H, Rha SW, Choi BG, Choi SY, Moon SK, Jang WY, Kim W, Ahn JH, Park SH, Choi WG, Yang RF, Bai WW, Choi CU, Ryu YG, Baek MJ, Oh DJ. Impact of chronic outward force on arterial responses of proximal and distal of long superficial femoral artery stent. BMC Cardiovasc Disord 2021;21:323. [PMID: 34193057 DOI: 10.1186/s12872-021-02141-z] [Reference Citation Analysis]
33 Nagaraja S, Sullivan SJ, Stafford PR, Lucas AD, Malkin E. Impact of nitinol stent surface processing on in-vivo nickel release and biological response. Acta Biomaterialia 2018;72:424-33. [DOI: 10.1016/j.actbio.2018.03.036] [Cited by in Crossref: 13] [Cited by in F6Publishing: 3] [Article Influence: 4.3] [Reference Citation Analysis]
34 Gray WA, Cardenas JA, Brodmann M, Werner M, Bernardo NI, George JC, Lansky A. Treating Post-Angioplasty Dissection in the Femoropopliteal Arteries Using the Tack Endovascular System. JACC: Cardiovascular Interventions 2019;12:2375-84. [DOI: 10.1016/j.jcin.2019.08.005] [Cited by in Crossref: 9] [Cited by in F6Publishing: 5] [Article Influence: 4.5] [Reference Citation Analysis]
35 Pieper CC, Sprinkart AM, Nadal J, Hippe V, Meyer C, Schild HH, Thomas D. Postinterventional passive expansion of partially dilated transjugular intrahepatic portosystemic shunt stents. J Vasc Interv Radiol. 2015;26:388-394. [PMID: 25541420 DOI: 10.1016/j.jvir.2014.10.021] [Cited by in Crossref: 24] [Cited by in F6Publishing: 16] [Article Influence: 3.4] [Reference Citation Analysis]
36 Dohi T, Schmidt A, Scheinert D, Bausback Y, Kabata D, Shintani A, Sakata Y, Steiner S. Drug-Coated Balloon Angioplasty in Atherosclerosis Patients With Popliteal Artery Involvement. J Endovasc Ther 2018;25:581-7. [DOI: 10.1177/1526602818786973] [Cited by in Crossref: 4] [Cited by in F6Publishing: 4] [Article Influence: 1.3] [Reference Citation Analysis]
37 Pieper CC, Jansen C, Meyer C, Nadal J, Lehmann J, Schild HH, Trebicka J, Thomas D. Prospective Evaluation of Passive Expansion of Partially Dilated Transjugular Intrahepatic Portosystemic Shunt Stent Grafts—A Three-Dimensional Sonography Study. Journal of Vascular and Interventional Radiology 2017;28:117-25. [DOI: 10.1016/j.jvir.2016.06.023] [Cited by in Crossref: 27] [Cited by in F6Publishing: 19] [Article Influence: 6.8] [Reference Citation Analysis]
38 Ball TC, Foerst JR, Vorpahl M, Powell RJ, Virmani R, Kaplan AV. Embolic Stroke after Carotid Stenting: Microscopic Computed Tomography Analysis of En Bloc Surgical Specimen Demonstrating Ulceration. Circulation 2010;121:1661-3. [DOI: 10.1161/cir.0b013e3181dabbac] [Cited by in Crossref: 6] [Cited by in F6Publishing: 1] [Article Influence: 0.5] [Reference Citation Analysis]
39 Ohki T, Angle JF, Yokoi H, Jaff MR, Popma J, Piegari G, Kanaoka Y, Ohki T, Angle JF, Feiring A, Nelson B, Glickman M, Guimaraes M, Hall P, Johnson S, Jordan W, Khoudoud O, Leung D, Mcgarvey J, Mckinsey J, Nowygrod R, Shammas N, Carey D, Iyengar S, Isenbarger D, Ali V, Ashchi M, Rivera E, Moursi M, Bachinsky W, Metzger C, Piegari G, Aronow H, Wiechmann B, Callicutt C, Gordon I, Chaille P, Espinoza A, Foster M, Sharafuddin M, Shah R, Bunch F, Harlin S, Iwabuchi M, Ando K, Kichikawa K, Muramatsu T, Urasawa K, Yokoi Y, Uematsu M, Lo P, Huang C, Kao H, Jae H. One-year outcomes of the U.S. and Japanese regulatory trial of the Misago stent for treatment of superficial femoral artery disease (OSPREY study). Journal of Vascular Surgery 2016;63:370-376.e1. [DOI: 10.1016/j.jvs.2015.08.093] [Cited by in Crossref: 16] [Cited by in F6Publishing: 9] [Article Influence: 3.2] [Reference Citation Analysis]
40 Nia NV, Fishbein GA, Levi DS. Can a self-expanding pediatric stent expand with an artery? Relationship of stent design to vascular biology. Catheter Cardiovasc Interv 2021;98:139-47. [PMID: 33825308 DOI: 10.1002/ccd.29679] [Reference Citation Analysis]
41 Ho KJ, Owens CD. Diagnosis, classification, and treatment of femoropopliteal artery in-stent restenosis. J Vasc Surg 2017;65:545-57. [PMID: 28126181 DOI: 10.1016/j.jvs.2016.09.031] [Cited by in Crossref: 15] [Cited by in F6Publishing: 9] [Article Influence: 3.8] [Reference Citation Analysis]
42 Fusaro M, Cassese S, Ndrepepa G, King LA, Tada T, Ott I, Kastrati A. Paclitaxel-coated balloon or primary bare nitinol stent for revascularization of femoropopliteal artery: A meta-analysis of randomized trials versus uncoated balloon and an adjusted indirect comparison. International Journal of Cardiology 2013;168:4002-9. [DOI: 10.1016/j.ijcard.2013.06.081] [Cited by in Crossref: 24] [Cited by in F6Publishing: 18] [Article Influence: 3.0] [Reference Citation Analysis]
43 Sullivan SJ, Madamba D, Sivan S, Miyashiro K, Dreher ML, Trépanier C, Nagaraja S. The effects of surface processing on in-vivo corrosion of Nitinol stents in a porcine model. Acta Biomaterialia 2017;62:385-96. [DOI: 10.1016/j.actbio.2017.08.029] [Cited by in Crossref: 13] [Cited by in F6Publishing: 7] [Article Influence: 3.3] [Reference Citation Analysis]