BPG is committed to discovery and dissemination of knowledge
Cited by in F6Publishing
For: Posada O, Tate R, Meek R, Grant M. In Vitro Analyses of the Toxicity, Immunological, and Gene Expression Effects of Cobalt-Chromium Alloy Wear Debris and Co Ions Derived from Metal-on-Metal Hip Implants. Lubricants 2015;3:539-68. [DOI: 10.3390/lubricants3030539] [Cited by in Crossref: 18] [Cited by in F6Publishing: 4] [Article Influence: 2.6] [Reference Citation Analysis]
Number Citing Articles
1 Herranz G, Berges C, Naranjo JA, García C, Garrido I. Mechanical performance, corrosion and tribological evaluation of a Co-Cr-Mo alloy processed by MIM for biomedical applications. J Mech Behav Biomed Mater 2020;105:103706. [PMID: 32279850 DOI: 10.1016/j.jmbbm.2020.103706] [Cited by in Crossref: 2] [Cited by in F6Publishing: 1] [Article Influence: 1.0] [Reference Citation Analysis]
2 Oskouei RH, Barati MR, Farhoudi H, Taylor M, Solomon LB. A new finding on the in-vivo crevice corrosion damage in a CoCrMo hip implant. Materials Science and Engineering: C 2017;79:390-8. [DOI: 10.1016/j.msec.2017.05.086] [Cited by in Crossref: 10] [Cited by in F6Publishing: 5] [Article Influence: 2.0] [Reference Citation Analysis]
3 Ryu JJ, Cudjoe E, Patel MV, Caputo M. Sliding Corrosion Fatigue of Metallic Joint Implants: A Comparative Study of CoCrMo and Ti6Al4V in Simulated Synovial Environments. Lubricants 2022;10:65. [DOI: 10.3390/lubricants10040065] [Reference Citation Analysis]
4 Jakovljević S, Alar V, Ivanković A. Electrochemical Behaviour of PACVD TiN-Coated CoCrMo Medical Alloy. Metals 2017;7:231. [DOI: 10.3390/met7070231] [Cited by in Crossref: 5] [Cited by in F6Publishing: 1] [Article Influence: 1.0] [Reference Citation Analysis]
5 Swiatkowska I, Martin NG, Henckel J, Apthorp H, Hamshere J, Hart AJ. Blood and plasma titanium levels associated with well-functioning hip implants. Journal of Trace Elements in Medicine and Biology 2020;57:9-17. [DOI: 10.1016/j.jtemb.2019.09.005] [Cited by in Crossref: 12] [Cited by in F6Publishing: 9] [Article Influence: 6.0] [Reference Citation Analysis]
6 Bandyopadhyay A, Ciliveri S, Bose S. Metal Additive Manufacturing for Load-Bearing Implants. J Indian Inst Sci. [DOI: 10.1007/s41745-021-00281-x] [Reference Citation Analysis]
7 Swiatkowska I, Martin N, Hart AJ. Blood titanium level as a biomarker of orthopaedic implant wear. J Trace Elem Med Biol 2019;53:120-8. [PMID: 30910194 DOI: 10.1016/j.jtemb.2019.02.013] [Cited by in Crossref: 20] [Cited by in F6Publishing: 14] [Article Influence: 6.7] [Reference Citation Analysis]