BPG is committed to discovery and dissemination of knowledge
Cited by in F6Publishing
For: Karageorgis A, Lenhard SC, Yerby B, Forsgren MF, Liachenko S, Johansson E, Pilling MA, Peterson RA, Yang X, Williams DP, Ungersma SE, Morgan RE, Brouwer KLR, Jucker BM, Hockings PD. A multi-center preclinical study of gadoxetate DCE-MRI in rats as a biomarker of drug induced inhibition of liver transporter function. PLoS One 2018;13:e0197213. [PMID: 29771932 DOI: 10.1371/journal.pone.0197213] [Cited by in Crossref: 9] [Cited by in F6Publishing: 7] [Article Influence: 2.3] [Reference Citation Analysis]
Number Citing Articles
1 Eliat PA. Editorial for "Noninvasive Assessment of APAP-Induced Hepatotoxicity Using Multiple MR Parameters in an Experimental Rat Model". J Magn Reson Imaging 2022. [PMID: 35404488 DOI: 10.1002/jmri.28200] [Reference Citation Analysis]
2 Vermeulen I, Isin EM, Barton P, Cillero-pastor B, Heeren RM. Multimodal molecular imaging in drug discovery and development. Drug Discovery Today 2022. [DOI: 10.1016/j.drudis.2022.04.009] [Cited by in Crossref: 2] [Cited by in F6Publishing: 1] [Article Influence: 2.0] [Reference Citation Analysis]
3 Anklam E, Bahl MI, Ball R, Beger RD, Cohen J, Fitzpatrick S, Girard P, Halamoda-Kenzaoui B, Hinton D, Hirose A, Hoeveler A, Honma M, Hugas M, Ishida S, Kass GE, Kojima H, Krefting I, Liachenko S, Liu Y, Masters S, Marx U, McCarthy T, Mercer T, Patri A, Pelaez C, Pirmohamed M, Platz S, Ribeiro AJ, Rodricks JV, Rusyn I, Salek RM, Schoonjans R, Silva P, Svendsen CN, Sumner S, Sung K, Tagle D, Tong L, Tong W, Eijnden-van-Raaij JVD, Vary N, Wang T, Waterton J, Wang M, Wen H, Wishart D, Yuan Y, Slikker W Jr. Emerging technologies and their impact on regulatory science. Exp Biol Med (Maywood) 2021;:15353702211052280. [PMID: 34783606 DOI: 10.1177/15353702211052280] [Reference Citation Analysis]
4 Scotcher D, Melillo N, Tadimalla S, Darwich AS, Ziemian S, Ogungbenro K, Schütz G, Sourbron S, Galetin A. Physiologically Based Pharmacokinetic Modeling of Transporter-Mediated Hepatic Disposition of Imaging Biomarker Gadoxetate in Rats. Mol Pharm 2021;18:2997-3009. [PMID: 34283621 DOI: 10.1021/acs.molpharmaceut.1c00206] [Reference Citation Analysis]
5 Wegrzyniak O, Rosestedt M, Eriksson O. Recent Progress in the Molecular Imaging of Nonalcoholic Fatty Liver Disease. Int J Mol Sci 2021;22:7348. [PMID: 34298967 DOI: 10.3390/ijms22147348] [Reference Citation Analysis]
6 Liachenko S. Translational imaging in toxicology. Current Opinion in Toxicology 2020;23-24:29-38. [DOI: 10.1016/j.cotox.2020.03.006] [Cited by in Crossref: 2] [Cited by in F6Publishing: 1] [Article Influence: 1.0] [Reference Citation Analysis]
7 Ziemian S, Green C, Sourbron S, Jost G, Schütz G, Hines CDG. Ex vivo gadoxetate relaxivities in rat liver tissue and blood at five magnetic field strengths from 1.41 to 7 T. NMR Biomed 2021;34:e4401. [PMID: 32851735 DOI: 10.1002/nbm.4401] [Cited by in Crossref: 2] [Cited by in F6Publishing: 2] [Article Influence: 1.0] [Reference Citation Analysis]
8 Hernández Lozano I, Langer O. Use of imaging to assess the activity of hepatic transporters. Expert Opin Drug Metab Toxicol 2020;16:149-64. [PMID: 31951754 DOI: 10.1080/17425255.2020.1718107] [Cited by in Crossref: 5] [Cited by in F6Publishing: 5] [Article Influence: 2.5] [Reference Citation Analysis]
9 Forsgren MF, Karlsson M, Dahlqvist Leinhard O, Dahlström N, Norén B, Romu T, Ignatova S, Ekstedt M, Kechagias S, Lundberg P, Cedersund G. Model-inferred mechanisms of liver function from magnetic resonance imaging data: Validation and variation across a clinically relevant cohort. PLoS Comput Biol 2019;15:e1007157. [PMID: 31237870 DOI: 10.1371/journal.pcbi.1007157] [Cited by in Crossref: 3] [Cited by in F6Publishing: 2] [Article Influence: 1.0] [Reference Citation Analysis]
10 Waterton JC, Hines CDG, Hockings PD, Laitinen I, Ziemian S, Campbell S, Gottschalk M, Green C, Haase M, Hassemer K, Juretschke HP, Koehler S, Lloyd W, Luo Y, Mahmutovic Persson I, O'Connor JPB, Olsson LE, Pindoria K, Schneider JE, Sourbron S, Steinmann D, Strobel K, Tadimalla S, Teh I, Veltien A, Zhang X, Schütz G. Repeatability and reproducibility of longitudinal relaxation rate in 12 small-animal MRI systems. Magn Reson Imaging 2019;59:121-9. [PMID: 30872166 DOI: 10.1016/j.mri.2019.03.008] [Cited by in Crossref: 6] [Cited by in F6Publishing: 6] [Article Influence: 2.0] [Reference Citation Analysis]