BPG is committed to discovery and dissemination of knowledge
Cited by in F6Publishing
For: Trompier F, Boschung M, Buffler A, Domingo C, Cale E, Chevallier MA, Esposito A, Ferrarini M, Geduld DR, Hager L, Hohmann E, Mayer S, Musso A, Romero-esposito M, Rottger S, Smit FD, Naik AS, Tanner R, Wissmann F, Caresana M. A comparison of the response of PADC neutron dosemeters in high-energy neutron fields. Radiation Protection Dosimetry 2014;161:78-81. [DOI: 10.1093/rpd/nct275] [Cited by in Crossref: 5] [Cited by in F6Publishing: 5] [Article Influence: 0.6] [Reference Citation Analysis]
Number Citing Articles
1 Stabilini A, Akselrod M, Fomenko V, Harrison J, Yukihara E. Principal Component Analysis applied to neutron dosimetry based on PADC detectors and FNTDs. Radiation Measurements 2021;141:106516. [DOI: 10.1016/j.radmeas.2021.106516] [Cited by in Crossref: 4] [Cited by in F6Publishing: 4] [Article Influence: 4.0] [Reference Citation Analysis]
2 García-fusté M, Devienne A, Romero-expósito M, Caballero-pacheco M, Domingo C. Calibration of neutron dosimeters for radiation protection use at the ALBA synchrotron experimental hall. Radiation Physics and Chemistry 2020;171:108749. [DOI: 10.1016/j.radphyschem.2020.108749] [Cited by in Crossref: 1] [Cited by in F6Publishing: 1] [Article Influence: 0.5] [Reference Citation Analysis]
3 Rühm W, Ainsbury E, Breustedt B, Caresana M, Gilvin P, Knežević Ž, Rabus H, Stolarczyk L, Vargas A, Bottollier-depois J, Harrison R, Lopez M, Stadtmann H, Tanner R, Vanhavere F, Woda C, Clairand I, Fantuzzi E, Fattibene P, Hupe O, Olko P, Olšovcová V, Schuhmacher H, Alves J, Miljanic S. The European radiation dosimetry group – Review of recent scientific achievements. Radiation Physics and Chemistry 2020;168:108514. [DOI: 10.1016/j.radphyschem.2019.108514] [Cited by in Crossref: 14] [Cited by in F6Publishing: 14] [Article Influence: 7.0] [Reference Citation Analysis]
4 Rühm W, Bottollier-depois J, Gilvin P, Harrison R, Knežević Ž, Lopez M, Tanner R, Vargas A, Woda C. The work programme of EURADOS on internal and external dosimetry. Ann ICRP 2018;47:20-34. [DOI: 10.1177/0146645318756224] [Cited by in Crossref: 16] [Cited by in F6Publishing: 16] [Article Influence: 4.0] [Reference Citation Analysis]
5 Nikezic D, Shahmohammadi Beni M, Krstic D, Yu KN. Characteristics of Protons Exiting from a Polyethylene Converter Irradiated by Neutrons with Energies between 1 keV and 10 MeV. PLoS One 2016;11:e0157627. [PMID: 27362656 DOI: 10.1371/journal.pone.0157627] [Cited by in Crossref: 8] [Cited by in F6Publishing: 8] [Article Influence: 1.3] [Reference Citation Analysis]