BPG is committed to discovery and dissemination of knowledge
Cited by in F6Publishing
For: Haga Y, Chida K, Kimura Y, Yamanda S, Sota M, Abe M, Kaga Y, Meguro T, Zuguchi M. Radiation eye dose to medical staff during respiratory endoscopy under X-ray fluoroscopy. J Radiat Res 2020;61:691-6. [PMID: 32657327 DOI: 10.1093/jrr/rraa034] [Cited by in Crossref: 11] [Cited by in F6Publishing: 11] [Article Influence: 5.5] [Reference Citation Analysis]
Number Citing Articles
1 Otomo K, Inaba Y, Abe K, Onodera M, Suzuki T, Sota M, Haga Y, Suzuki M, Zuguchi M, Chida K. Spatial Scattering Radiation to the Radiological Technologist during Medical Mobile Radiography. Bioengineering (Basel) 2023;10. [PMID: 36829753 DOI: 10.3390/bioengineering10020259] [Reference Citation Analysis]
2 Hattori K, Inaba Y, Kato T, Fujisawa M, Yasuno H, Yamada A, Haga Y, Suzuki M, Zuguchi M, Chida K. Evaluation of a New Real-Time Dosimeter Sensor for Interventional Radiology Staff. Sensors (Basel) 2023;23. [PMID: 36617110 DOI: 10.3390/s23010512] [Reference Citation Analysis]
3 Yashima S, Chida K. Awareness of Medical Radiologic Technologists of Ionizing Radiation and Radiation Protection. Int J Environ Res Public Health 2022;20. [PMID: 36612833 DOI: 10.3390/ijerph20010497] [Cited by in Crossref: 1] [Cited by in F6Publishing: 1] [Article Influence: 1.0] [Reference Citation Analysis]
4 Morishima Y, Chida K, Meguro T, Hirota M, Chiba H, Fukuda H. Lens Equivalent dose of Staff During Endoscopic Retrograde Cholangiopancreatography: Dose Comparison Using Two Types of Dosemeters. Radiat Prot Dosimetry 2022:ncac160. [PMID: 36055968 DOI: 10.1093/rpd/ncac160] [Reference Citation Analysis]
5 Hirakawa M, Nakatake H, Tsuruta S, Matsuura S, Motomura Y, Hiraki Y, Mimori K, Ishigami K. Dosimetry of Occupational Eye Lens Dose Using a Novel Direct Eye Dosimeter, DOSIRIS, during Interventional Radiology Procedures. Interventional Radiology 2022;7:40-43. [DOI: 10.22575/interventionalradiology.2022-0005] [Reference Citation Analysis]
6 Chida K. What are useful methods to reduce occupational radiation exposure among radiological medical workers, especially for interventional radiology personnel? Radiol Phys Technol 2022. [PMID: 35608759 DOI: 10.1007/s12194-022-00660-8] [Cited by in Crossref: 2] [Cited by in F6Publishing: 3] [Article Influence: 2.0] [Reference Citation Analysis]
7 Inaba Y, Hitachi S, Watanuki M, Chida K. Radiation Eye Dose for Physicians in CT Fluoroscopy-Guided Biopsy. Tomography 2022;8:438-46. [DOI: 10.3390/tomography8010036] [Cited by in Crossref: 4] [Cited by in F6Publishing: 4] [Article Influence: 4.0] [Reference Citation Analysis]
8 Ishii H, Chida K, Satsurai K, Haga Y, Kaga Y, Abe M, Inaba Y, Zuguchi M. Occupational eye dose correlation with neck dose and patient-related quantities in interventional cardiology procedures. Radiol Phys Technol. [DOI: 10.1007/s12194-022-00650-w] [Cited by in Crossref: 4] [Cited by in F6Publishing: 2] [Article Influence: 4.0] [Reference Citation Analysis]
9 Kato M, Chida K, Munehisa M, Sato T, Inaba Y, Suzuki M, Zuguchi M. Non-Lead Protective Aprons for the Protection of Interventional Radiology Physicians from Radiation Exposure in Clinical Settings: An Initial Study. Diagnostics (Basel) 2021;11:1613. [PMID: 34573955 DOI: 10.3390/diagnostics11091613] [Cited by in Crossref: 7] [Cited by in F6Publishing: 7] [Article Influence: 3.5] [Reference Citation Analysis]
10 Endo M, Haga Y, Sota M, Tanaka A, Otomo K, Murabayashi Y, Abe M, Kaga Y, Inaba Y, Suzuki M, Meguro T, Chida K. Evaluation of novel X-ray protective eyewear in reducing the eye dose to interventional radiology physicians. J Radiat Res 2021;62:414-9. [PMID: 33839782 DOI: 10.1093/jrr/rrab014] [Cited by in Crossref: 12] [Cited by in F6Publishing: 12] [Article Influence: 6.0] [Reference Citation Analysis]
11 Ota J, Yokota H, Kawasaki T, Taoka J, Kato H, Chida K, Masuda Y, Uno T. Evaluation of Radiation Protection Methods for Assistant Staff during CT Imaging in High-energy Trauma: Lens Dosimetry with a Phantom Study. Health Phys 2021;120:635-40. [PMID: 33879645 DOI: 10.1097/HP.0000000000001391] [Cited by in Crossref: 7] [Cited by in F6Publishing: 8] [Article Influence: 3.5] [Reference Citation Analysis]
12 Matsubara K, Yoshida S, Hirosawa A, Chusin T, Furukawa Y. Characterization of Small Dosimeters Used for Measurement of Eye Lens Dose for Medical Staff during Fluoroscopic Examination. Diagnostics (Basel) 2021;11:150. [PMID: 33498545 DOI: 10.3390/diagnostics11020150] [Cited by in Crossref: 5] [Cited by in F6Publishing: 5] [Article Influence: 2.5] [Reference Citation Analysis]