BPG is committed to discovery and dissemination of knowledge
Cited by in F6Publishing
For: Nutalapati V, Kanakadandi V, Desai M, Olyaee M, Rastogi A. Cap-assisted colonoscopy: a meta-analysis of high-quality randomized controlled trials. EndoscInt Open. 2018;6:E1214-E1223. [PMID: 30302379 DOI: 10.1055/a-0650-4258] [Cited by in Crossref: 15] [Cited by in F6Publishing: 9] [Article Influence: 3.0] [Reference Citation Analysis]
Number Citing Articles
1 Cheng TF, Cheng KS. A randomized prospective study comparing single-balloon-assisted colonoscopy and cap-assisted colonoscopy in patients with previous incomplete conventional colonoscopy. J Gastroenterol Hepatol 2022. [PMID: 36398729 DOI: 10.1111/jgh.16062] [Reference Citation Analysis]
2 Ko J, Kim HW, Kang DH, Choi CW, Han SH, Ko BG. Efficacy of combination colonoscopy using modified cap-assisted and water-exchange colonoscopy with prone position for detection of colorectal adenomas. Medicine (Baltimore) 2022;101:e31271. [PMID: 36397393 DOI: 10.1097/MD.0000000000031271] [Reference Citation Analysis]
3 Hong SW, Hong HS, Kim K, Oh K, Lee JY, Park JH, Hwang SW, Park SH, Yang DH, Ye BD, Myung SJ, Yang SK, Byeon JS. Improved adenoma detection by a novel distal attachment device-assisted colonoscopy: a prospective randomized controlled trial. Gastrointest Endosc 2022;96:543-552.e1. [PMID: 35500658 DOI: 10.1016/j.gie.2022.04.1307] [Reference Citation Analysis]
4 Desai M, Rex DK, Bohm ME, Davitkov P, DeWitt JM, Fischer M, Faulx G, Heath R, Imler TD, James-Stevenson TN, Kahi CJ, Kessler WR, Kohli DR, McHenry L, Rai T, Rogers NA, Sagi SV, Sathyamurthy A, Vennalaganti P, Sundaram S, Patel H, Higbee A, Kennedy K, Lahr R, Stojadinovikj G, Dasari C, Parasa S, Faulx A, Sharma P. High-Definition Colonoscopy Compared With Cuff- and Cap-Assisted Colonoscopy: Results From a Multicenter, Prospective, Randomized Controlled Trial. Clin Gastroenterol Hepatol 2022;20:2023-2031.e6. [PMID: 34979245 DOI: 10.1016/j.cgh.2021.12.037] [Cited by in Crossref: 2] [Cited by in F6Publishing: 2] [Article Influence: 2.0] [Reference Citation Analysis]
5 Miyaguchi K, Tsuzuki Y, Hirooka N, Shiomi R, Ohgo H, Nakamoto H, Imaeda H. Endo-wing versus transparent hood-assisted colonoscopy for colorectal adenoma detection: A randomized controlled trial. J Gastroenterol Hepatol 2022;37:766-72. [PMID: 35174541 DOI: 10.1111/jgh.15805] [Reference Citation Analysis]
6 Ko J. Suggestion of a standard maneuver in cap-assisted colonoscopy: hooking and dragging maneuver. Endoscopy 2022;54:E164-5. [PMID: 33910249 DOI: 10.1055/a-1446-8180] [Reference Citation Analysis]
7 Dos Santos CEO, Malaman D, Arciniegas Sanmartin ID, Onófrio FDQ, Pereira-Lima JC. Effect of Linked-color Imaging on the Detection of Adenomas in Screening Colonoscopies. J Clin Gastroenterol 2022;56:e268-72. [PMID: 34406173 DOI: 10.1097/MCG.0000000000001601] [Cited by in Crossref: 3] [Article Influence: 3.0] [Reference Citation Analysis]
8 Ko J, Ko BG, Han SH, Kim HW. Effect of combined cap-assisted, water-aided, and prone position colonoscopy for adenoma detection: A retrospective study.. [DOI: 10.1101/2020.10.23.20218263] [Reference Citation Analysis]
9 Wen Q, Liu KJ, Cui BT, Li P, Wu X, Zhong M, Wei L, Tu H, Yuan Y, Lin D, Hsu WH, Wu DC, Yin H, Zhang FM. Impact of cap-assisted colonoscopy during transendoscopic enteral tubing: A randomized controlled trial. World J Gastroenterol 2020; 26(39): 6098-6110 [PMID: 33132658 DOI: 10.3748/wjg.v26.i39.6098] [Cited by in CrossRef: 5] [Cited by in F6Publishing: 4] [Article Influence: 1.7] [Reference Citation Analysis]
10 Seo JY, Jin EH, Bae JH, Lim JH, Chung GE, Lee C, Kwak MS, Kang HY, Song JH, Yang SY, Yang JI, Lim SH, Yim JY, Kim JS, Chung SJ. Multidirectional Colonoscopy Quality Improvement Increases Adenoma Detection Rate: Results of the Seoul National University Hospital Healthcare System Gangnam Center Colonoscopy Quality Upgrade Project (Gangnam-CUP). Dig Dis Sci 2020;65:1806-15. [PMID: 31732905 DOI: 10.1007/s10620-019-05944-5] [Cited by in Crossref: 5] [Cited by in F6Publishing: 4] [Article Influence: 1.7] [Reference Citation Analysis]
11 Ciuti G, Skonieczna-Żydecka K, Marlicz W, Iacovacci V, Liu H, Stoyanov D, Arezzo A, Chiurazzi M, Toth E, Thorlacius H, Dario P, Koulaouzidis A. Frontiers of Robotic Colonoscopy: A Comprehensive Review of Robotic Colonoscopes and Technologies. J Clin Med 2020;9:E1648. [PMID: 32486374 DOI: 10.3390/jcm9061648] [Cited by in Crossref: 38] [Cited by in F6Publishing: 45] [Article Influence: 12.7] [Reference Citation Analysis]
12 Anderson JC. Cap-Assisted Chromo-Colonoscopy: Are 2 Techniques Better Than None? Am J Gastroenterol 2020;115:365-6. [PMID: 32142483 DOI: 10.14309/ajg.0000000000000543] [Reference Citation Analysis]
13 Aziz M, Desai M, Hassan S, Fatima R, Dasari CS, Chandrasekar VT, Jegadeesan R, Duvvuri A, Patel H, Rai T, Sathyamurthy A, Kohli DR, Vennalaganti P, Nawras A, Wallace M, Sharma P. Improving serrated adenoma detection rate in the colon by electronic chromoendoscopy and distal attachment: systematic review and meta-analysis. Gastrointest Endosc 2019;90:721-731.e1. [PMID: 31288029 DOI: 10.1016/j.gie.2019.06.041] [Cited by in Crossref: 16] [Cited by in F6Publishing: 18] [Article Influence: 4.0] [Reference Citation Analysis]
14 Tziatzios G, Gkolfakis P, Triantafyllou K. Meta-analysis results in a 'cap' of confusion. Endosc Int Open 2019;7:E1143. [PMID: 31475232 DOI: 10.1055/a-0889-7650] [Reference Citation Analysis]
15 Shergill AK, Harris Adamson C. Failure of an engineered system: The gastrointestinal endoscope. Techniques in Gastrointestinal Endoscopy 2019;21:116-23. [DOI: 10.1016/j.tgie.2019.02.001] [Cited by in Crossref: 15] [Cited by in F6Publishing: 7] [Article Influence: 3.8] [Reference Citation Analysis]