BPG is committed to discovery and dissemination of knowledge
Cited by in F6Publishing
For: Schmidt T, Rosenthal D, Reinhartz O, Riemer K, He F, Hsia T, Marsden A, Kung E. Superior performance of continuous over pulsatile flow ventricular assist devices in the single ventricle circulation: A computational study. Journal of Biomechanics 2017;52:48-54. [DOI: 10.1016/j.jbiomech.2016.12.003] [Cited by in Crossref: 11] [Cited by in F6Publishing: 7] [Article Influence: 2.2] [Reference Citation Analysis]
Number Citing Articles
1 Chi Z, Beile L, Deyu L, Yubo F. Application of multiscale coupling models in the numerical study of circulation system. Medicine in Novel Technology and Devices 2022. [DOI: 10.1016/j.medntd.2022.100117] [Reference Citation Analysis]
2 Pinney SP, Chen JM. Pediatric Ventricular Assist Devices: A Quarter-Century of Support, Yet So Far to Go. J Am Coll Cardiol 2018;72:416-8. [PMID: 30025577 DOI: 10.1016/j.jacc.2018.05.025] [Cited by in Crossref: 1] [Article Influence: 0.3] [Reference Citation Analysis]
3 Friedland-Little JM, Joong A, Shugh SB, O'Connor MJ, Bansal N, Davies RR, Ploutz MS. Patient and Device Selection in Pediatric MCS: A Review of Current Consensus and Unsettled Questions. Pediatr Cardiol 2022. [PMID: 35325280 DOI: 10.1007/s00246-022-02880-6] [Reference Citation Analysis]
4 Maeda K, Nasirov T, Yarlagadda V, Hollander SA, Navaratnam M, Rosenthal DN, Dykes JC, Kaufman BD, Almond CS, Reinhartz O, Murray J, Chen S. Single Ventricular Assist Device Support for the Failing Bidirectional Glenn Patient. The Annals of Thoracic Surgery 2020;110:1659-66. [DOI: 10.1016/j.athoracsur.2019.12.088] [Cited by in Crossref: 6] [Cited by in F6Publishing: 3] [Article Influence: 3.0] [Reference Citation Analysis]
5 Mirzaei E, Farahmand M, Kung E. An algorithm for coupling multibranch in vitro experiment to numerical physiology simulation for a hybrid cardiovascular model. Int J Numer Method Biomed Eng 2020;36:e3289. [PMID: 31816194 DOI: 10.1002/cnm.3289] [Cited by in Crossref: 2] [Article Influence: 0.7] [Reference Citation Analysis]
6 Villa CR, Lorts A, Riggs KW, Alten J, Morales DL. How small can you go? A 2.5-kg infant with pulmonary atresia and coronary atresia bridged to cardiac transplantation with a paracorporeal-continuous flow ventricular assist device. The Journal of Thoracic and Cardiovascular Surgery 2019;158:e67-9. [DOI: 10.1016/j.jtcvs.2018.09.027] [Cited by in Crossref: 3] [Cited by in F6Publishing: 3] [Article Influence: 1.0] [Reference Citation Analysis]
7 Chen S, Rosenthal DN, Murray J, Dykes JC, Almond CS, Yarlagadda VV, Wright G, Navaratnam M, Reinhartz O, Maeda K. Bridge to Transplant with Ventricular Assist Device Support in Pediatric Patients with Single Ventricle Heart Disease. ASAIO J 2020;66:205-11. [PMID: 30864969 DOI: 10.1097/MAT.0000000000000983] [Cited by in Crossref: 15] [Cited by in F6Publishing: 3] [Article Influence: 7.5] [Reference Citation Analysis]
8 Andersen ND, Kirmani S, Turek JW. Commentary: Shunted single-ventricle neonatal ventricular-assist device support: Are we nearing a consensus strategy? The Journal of Thoracic and Cardiovascular Surgery 2019;158:e71-2. [DOI: 10.1016/j.jtcvs.2019.04.101] [Cited by in Crossref: 1] [Cited by in F6Publishing: 1] [Article Influence: 0.3] [Reference Citation Analysis]
9 Garven E, Rodell CB, Shema K, Govender K, Cassel SE, Ferrick B, Kupsho G, Kung E, Spiller KL, Stevens R, Throckmorton AL. Tunable Blood Shunt for Neonates With Complex Congenital Heart Defects. Front Bioeng Biotechnol 2022;9:734310. [DOI: 10.3389/fbioe.2021.734310] [Reference Citation Analysis]
10 Kaufmann J, Kung E. Factors Affecting Cardiovascular Physiology in Cardiothoracic Surgery: Implications for Lumped-Parameter Modeling. Front Surg 2019;6:62. [PMID: 31750311 DOI: 10.3389/fsurg.2019.00062] [Cited by in Crossref: 4] [Cited by in F6Publishing: 2] [Article Influence: 1.3] [Reference Citation Analysis]
11 Davies RR. Another step toward successful mechanical support of neonatal patients with single-ventricle circulation. J Thorac Cardiovasc Surg 2018;156:e175-6. [PMID: 29945736 DOI: 10.1016/j.jtcvs.2018.05.022] [Reference Citation Analysis]
12 Puri K, Adachi I. Mechanical Support for The Failing Single Ventricle at Pre-Fontan Stage: Current State of The Field and Future Directions. Semin Thorac Cardiovasc Surg Pediatr Card Surg Annu 2021;24:10-8. [PMID: 34116776 DOI: 10.1053/j.pcsu.2021.04.004] [Cited by in Crossref: 1] [Cited by in F6Publishing: 1] [Article Influence: 1.0] [Reference Citation Analysis]