BPG is committed to discovery and dissemination of knowledge
Cited by in F6Publishing
For: Yu YH, Han DS, Kim HS, Kim EK, Eun CS, Yoo KS, Shin WJ, Ryu S. Efficacy of bispectral index monitoring during balanced propofol sedation for colonoscopy: a prospective, randomized controlled trial. Dig Dis Sci. 2013;58:3576-3583. [PMID: 23982208 DOI: 10.1007/s10620-013-2833-4] [Cited by in Crossref: 11] [Cited by in F6Publishing: 12] [Article Influence: 1.2] [Reference Citation Analysis]
Number Citing Articles
1 Park JH, Lee SE, Kang E, Park YH, Lee HS, Lee SJ, Shin D, Noh GJ, Lee IH, Lee KH. Effect of depth of anesthesia on the phase lag entropy in patients undergoing general anesthesia by propofol: A STROBE-compliant study. Medicine (Baltimore) 2020;99:e21303. [PMID: 32791716 DOI: 10.1097/MD.0000000000021303] [Cited by in Crossref: 1] [Article Influence: 0.5] [Reference Citation Analysis]
2 Sargin M, Uluer MS, Şimşek B. The effect of bispectral index monitoring on cognitive performance following sedation for outpatient colonoscopy: a randomized controlled trial. Sao Paulo Med J 2019;137:305-11. [PMID: 31508796 DOI: 10.1590/1516-3180.2018.0383210519] [Cited by in Crossref: 2] [Cited by in F6Publishing: 3] [Article Influence: 0.7] [Reference Citation Analysis]
3 Conway A, Sutherland J. Depth of anaesthesia monitoring during procedural sedation and analgesia: A systematic review and meta-analysis. Int J Nurs Stud 2016;63:201-12. [PMID: 27236824 DOI: 10.1016/j.ijnurstu.2016.05.004] [Cited by in Crossref: 13] [Cited by in F6Publishing: 7] [Article Influence: 2.2] [Reference Citation Analysis]
4 Song HY, Li JX, Liu J, Zheng JQ, Wang X, Wang CH, Zhang GX. Patient-controlled analgesia and sedation with remifentanil-propofol mixture for colonoscopy. Shijie Huaren Xiaohua Zazhi 2014; 22(29): 4519-4524 [DOI: 10.11569/wcjd.v22.i29.4519] [Reference Citation Analysis]
5 Sheahan C, Mathews D. Monitoring and delivery of sedation. British Journal of Anaesthesia 2014;113:ii37-47. [DOI: 10.1093/bja/aeu378] [Cited by in Crossref: 52] [Cited by in F6Publishing: 36] [Article Influence: 6.5] [Reference Citation Analysis]
6 Yoldas H, Yildiz I, Karagoz I, Sit M, Ogun MN, Demirhan A, Bilgi M. Effects of Bispectral Index-controlled Use of Magnesium on Propofol Consumption and Sedation Level in Patients Undergoing Colonoscopy. Medeni Med J 2019;34:380-6. [PMID: 32821465 DOI: 10.5222/MMJ.2019.99705] [Cited by in Crossref: 1] [Cited by in F6Publishing: 1] [Article Influence: 0.3] [Reference Citation Analysis]
7 El sayed AA, Assad OM, El tahawy MS. Comparative study between dexmedetomidine-ketamine and fentanyl-ketamine combinations for sedation in patients undergoing extracorporeal shock wave lithotripsy. A randomized double blinded study. Egyptian Journal of Anaesthesia 2019;31:35-41. [DOI: 10.1016/j.egja.2014.11.001] [Cited by in Crossref: 2] [Cited by in F6Publishing: 1] [Article Influence: 0.7] [Reference Citation Analysis]
8 Park SW, Lee H, Ahn H. Bispectral Index Versus Standard Monitoring in Sedation for Endoscopic Procedures: A Systematic Review and Meta-Analysis. Dig Dis Sci. 2016;61:814-824. [PMID: 26531839 DOI: 10.1007/s10620-015-3945-9] [Cited by in Crossref: 20] [Cited by in F6Publishing: 12] [Article Influence: 2.9] [Reference Citation Analysis]
9 Heo J, Jung MK, Lee HS, Cho CM, Jeon SW, Kim SK, Jeon YH. Effects of bispectral index monitoring as an adjunct to nurse-administered propofol combined sedation during colonoscopy: a randomized clinical trial. Korean J Intern Med 2016;31:260-6. [PMID: 26932401 DOI: 10.3904/kjim.2014.077] [Cited by in Crossref: 4] [Cited by in F6Publishing: 3] [Article Influence: 0.7] [Reference Citation Analysis]
10 Zhang H, Lu Y, Wang L, Lv J, Ma Y, Wang W, Li G, Li Y. Bispectral index monitoring of sedation depth during endoscopy: a meta-analysis with trial sequential analysis of randomized controlled trials. Minerva Anestesiol 2019;85. [DOI: 10.23736/s0375-9393.18.13227-5] [Cited by in Crossref: 4] [Cited by in F6Publishing: 2] [Article Influence: 1.3] [Reference Citation Analysis]
11 Lee TH, Lee CK. Endoscopic sedation: from training to performance. Clin Endosc 2014;47:141-50. [PMID: 24765596 DOI: 10.5946/ce.2014.47.2.141] [Cited by in Crossref: 13] [Cited by in F6Publishing: 8] [Article Influence: 1.6] [Reference Citation Analysis]
12 He W, Huang RR, Shi QY, Liu XB, Wang JA, Yan M. Bispectral index-guided sedation in transfemoral transcatheter aortic valve implantation: a retrospective control study. J Zhejiang Univ Sci B 2017;18:353-9. [PMID: 28378573 DOI: 10.1631/jzus.B1600522] [Cited by in Crossref: 3] [Article Influence: 0.6] [Reference Citation Analysis]