BPG is committed to discovery and dissemination of knowledge
Cited by in F6Publishing
For: Geber-Bergstrand T, Bernhardsson C, Christiansson M, Mattsson S, Rääf CL. Optically stimulated luminescence (OSL) dosimetry in irradiated alumina substrates from mobile phone resistors. Radiat Environ Biophys 2018;57:69-75. [PMID: 29255926 DOI: 10.1007/s00411-017-0725-2] [Cited by in Crossref: 8] [Cited by in F6Publishing: 3] [Article Influence: 1.6] [Reference Citation Analysis]
Number Citing Articles
1 Chandler J, Sholom S, Mckeever S, Bakhanova E, Chumak V, Velásquez D, Hall H. Dose conversion factors for absorbed dose in a mobile phone to absorbed dose in critical organs in an anthropomorphic phantom for emergency dosimetry applications: OSL and TL experimental results, and Monte Carlo simulations. Radiation Measurements 2022. [DOI: 10.1016/j.radmeas.2022.106781] [Reference Citation Analysis]
2 Sholom S, Mckeever S. OSL with chips from US credit cards. Radiation Measurements 2021;141:106536. [DOI: 10.1016/j.radmeas.2021.106536] [Cited by in Crossref: 2] [Cited by in F6Publishing: 1] [Article Influence: 2.0] [Reference Citation Analysis]
3 Maltar-Strmečki N, Vidotto M, Della Monaca S, Erceg I, Fattibene P, Vojnić Kortmiš M, Quattrini MC, Bortolin E. Salty Crackers as Fortuitous Dosimeters: A Novel PSL Method for Rapid Radiation Triage. Front Public Health 2021;9:661376. [PMID: 33898384 DOI: 10.3389/fpubh.2021.661376] [Reference Citation Analysis]
4 McKeever SWS, Sholom S, Chandler JR. DEVELOPMENTS IN THE USE OF THERMOLUMINESCENCE AND OPTICALLY STIMULATED LUMINESCENCE FROM MOBILE PHONES IN EMERGENCY DOSIMETRY. Radiat Prot Dosimetry 2020;192:205-35. [PMID: 33406531 DOI: 10.1093/rpd/ncaa208] [Cited by in Crossref: 3] [Article Influence: 1.5] [Reference Citation Analysis]
5 Van Hoey O, Römkens D, Eakins J, Kouroukla E, Discher M, Vanhavere F. Uncertainty evaluation for organ dose assessment with optically stimulated luminescence measurements on mobile phone resistors after a radiological incident. Radiation Measurements 2021;141:106520. [DOI: 10.1016/j.radmeas.2021.106520] [Cited by in Crossref: 3] [Cited by in F6Publishing: 2] [Article Influence: 3.0] [Reference Citation Analysis]
6 Guidelli EJ, Lima IS, Baffa O. Monosodium glutamate for accidental, retrospective, and medical dosimetry using electron spin resonance. Radiat Environ Biophys 2018;57:349-56. [PMID: 30242477 DOI: 10.1007/s00411-018-0756-3] [Cited by in Crossref: 3] [Cited by in F6Publishing: 1] [Article Influence: 0.8] [Reference Citation Analysis]
7 Sholom S, Mckeever S. A non-destructive, high-sensitivity, emergency dosimetry method using OSL from protective back-glasses from smartphones. Radiation Measurements 2021;147:106646. [DOI: 10.1016/j.radmeas.2021.106646] [Cited by in Crossref: 1] [Article Influence: 1.0] [Reference Citation Analysis]
8 Hayes RB, O'mara RP. Retrospective dosimetry at the natural background level with commercial surface mount resistors. Radiation Measurements 2019;121:42-8. [DOI: 10.1016/j.radmeas.2018.12.007] [Cited by in Crossref: 4] [Cited by in F6Publishing: 3] [Article Influence: 1.3] [Reference Citation Analysis]