BPG is committed to discovery and dissemination of knowledge
Cited by in F6Publishing
For: Watanabe J, Ota M, Suwa Y, Suzuki S, Suwa H, Momiyama M, Ishibe A, Watanabe K, Masui H, Nagahori K, Ichikawa Y, Endo I. Evaluation of the intestinal blood flow near the rectosigmoid junction using the indocyanine green fluorescence method in a colorectal cancer surgery. Int J Colorectal Dis 2015;30:329-35. [DOI: 10.1007/s00384-015-2129-6] [Cited by in Crossref: 36] [Cited by in F6Publishing: 28] [Article Influence: 5.1] [Reference Citation Analysis]
Number Citing Articles
1 James DR, Ris F, Yeung TM, Kraus R, Buchs NC, Mortensen NJ, Hompes RJ. Fluorescence angiography in laparoscopic low rectal and anorectal anastomoses with pinpoint perfusion imaging--a critical appraisal with specific focus on leak risk reduction. Colorectal Dis. 2015;17 Suppl 3:16-21. [PMID: 26394738 DOI: 10.1111/codi.13033] [Cited by in Crossref: 26] [Cited by in F6Publishing: 23] [Article Influence: 4.3] [Reference Citation Analysis]
2 Ishii M, Hamabe A, Okita K, Nishidate T, Okuya K, Usui A, Akizuki E, Satoyoshi T, Takemasa I. Efficacy of indocyanine green fluorescence angiography in preventing anastomotic leakage after laparoscopic colorectal cancer surgery. Int J Colorectal Dis 2020;35:269-75. [DOI: 10.1007/s00384-019-03482-0] [Cited by in Crossref: 9] [Cited by in F6Publishing: 8] [Article Influence: 3.0] [Reference Citation Analysis]
3 Nakashima K, Ryu S, Okamoto A, Hara K, Ishida K, Ito R, Nakabayashi Y. Usefulness of blood flow evaluation with indocyanine green fluorescence imaging during laparoscopic surgery for strangulated bowel obstruction: A cohort study. Asian J Surg 2021:S1015-9584(21)00522-4. [PMID: 34518078 DOI: 10.1016/j.asjsur.2021.08.020] [Cited by in Crossref: 1] [Article Influence: 1.0] [Reference Citation Analysis]
4 Du CZ, Fan ZH, Yang YF, Yuan P, Gu J. Value of intra-operative Doppler sonographic measurements in predicting post-operative anastomotic leakage in rectal cancer: a prospective pilot study. Chin Med J (Engl) 2019;132:2168-76. [PMID: 31461731 DOI: 10.1097/CM9.0000000000000410] [Cited by in Crossref: 2] [Cited by in F6Publishing: 1] [Article Influence: 1.0] [Reference Citation Analysis]
5 Keller DS, Ishizawa T, Cohen R, Chand M. Indocyanine green fluorescence imaging in colorectal surgery: overview, applications, and future directions. The Lancet Gastroenterology & Hepatology 2017;2:757-66. [DOI: 10.1016/s2468-1253(17)30216-9] [Cited by in Crossref: 48] [Cited by in F6Publishing: 19] [Article Influence: 9.6] [Reference Citation Analysis]
6 Losurdo P, Mis TC, Cosola D, Bonadio L, Giudici F, Casagranda B, Bortul M, de Manzini N. Anastomosis Leak: Is There Still a Place for Indocyanine Green Fluorescence Imaging in Colon-Rectal Surgery?Surg Innov. 2020;1553350620975258. [PMID: 33236661 DOI: 10.1177/1553350620975258] [Cited by in Crossref: 1] [Cited by in F6Publishing: 2] [Article Influence: 0.5] [Reference Citation Analysis]
7 DSouza AV, Lin H, Henderson ER, Samkoe KS, Pogue BW. Review of fluorescence guided surgery systems: identification of key performance capabilities beyond indocyanine green imaging. J Biomed Opt 2016;21:80901. [PMID: 27533438 DOI: 10.1117/1.JBO.21.8.080901] [Cited by in Crossref: 184] [Cited by in F6Publishing: 91] [Article Influence: 46.0] [Reference Citation Analysis]
8 Anayama T, Sato T, Hirohashi K, Miyazaki R, Yamamoto M, Okada H, Orihashi K, Inoue K, Kobayashi M, Yoshida M, Hanazaki K. Near-infrared fluorescent solid material for visualizing indwelling devices implanted for medical use. Surg Endosc 2020;34:4206-13. [PMID: 32430529 DOI: 10.1007/s00464-020-07634-0] [Cited by in Crossref: 2] [Cited by in F6Publishing: 3] [Article Influence: 1.0] [Reference Citation Analysis]
9 Kim JC, Lee JL, Park SH. Interpretative Guidelines and Possible Indications for Indocyanine Green Fluorescence Imaging in Robot-Assisted Sphincter-Saving Operations. Dis Colon Rectum. 2017;60:376-384. [PMID: 28267004 DOI: 10.1097/dcr.0000000000000782] [Cited by in Crossref: 26] [Cited by in F6Publishing: 9] [Article Influence: 5.2] [Reference Citation Analysis]
10 Carmichael JC, Mills S. Anatomy and Embryology of the Colon, Rectum, and Anus. In: Steele SR, Hull TL, Read TE, Saclarides TJ, Senagore AJ, Whitlow CB, editors. The ASCRS Textbook of Colon and Rectal Surgery. Cham: Springer International Publishing; 2016. pp. 3-26. [DOI: 10.1007/978-3-319-25970-3_1] [Cited by in Crossref: 6] [Cited by in F6Publishing: 1] [Article Influence: 1.0] [Reference Citation Analysis]
11 Kojima S, Sakamoto T, Nagai Y, Matsui Y, Nambu K, Masamune K. Laser Speckle Contrast Imaging for Intraoperative Quantitative Assessment of Intestinal Blood Perfusion During Colorectal Surgery: A Prospective Pilot Study. Surg Innov 2019;26:293-301. [PMID: 30638132 DOI: 10.1177/1553350618823426] [Cited by in Crossref: 4] [Cited by in F6Publishing: 5] [Article Influence: 1.3] [Reference Citation Analysis]
12 Mizrahi I, Abu-gazala M, Rickles AS, Fernandez LM, Petrucci A, Wolf J, Sands DR, Wexner SD. Indocyanine green fluorescence angiography during low anterior resection for low rectal cancer: results of a comparative cohort study. Tech Coloproctol 2018;22:535-40. [DOI: 10.1007/s10151-018-1832-z] [Cited by in Crossref: 28] [Cited by in F6Publishing: 24] [Article Influence: 7.0] [Reference Citation Analysis]
13 Hamabe A, Ogino T, Tanida T, Noura S, Morita S, Dono K. Indocyanine green fluorescence-guided laparoscopic surgery, with omental appendices as fluorescent markers for colorectal cancer resection: a pilot study. Surg Endosc 2019;33:669-78. [DOI: 10.1007/s00464-018-6504-6] [Cited by in Crossref: 4] [Cited by in F6Publishing: 3] [Article Influence: 1.0] [Reference Citation Analysis]
14 Su H, Wu H, Bao M, Luo S, Wang X, Zhao C, Liu Q, Wang X, Zhou Z, Zhou H. Indocyanine green fluorescence imaging to assess bowel perfusion during totally laparoscopic surgery for colon cancer. BMC Surg 2020;20:102. [PMID: 32404083 DOI: 10.1186/s12893-020-00745-4] [Cited by in Crossref: 9] [Cited by in F6Publishing: 6] [Article Influence: 4.5] [Reference Citation Analysis]
15 Sandler BJ, Sherwinter D, Panait L, Parent R, Schwartz J, Renton D. SAGES Technology and Value Assessment Committee safety and effectiveness analysis on immunofluorescence in the operating room for biliary visualization and perfusion assessment. Surg Endosc 2017;31:3801-10. [DOI: 10.1007/s00464-017-5638-2] [Cited by in Crossref: 1] [Cited by in F6Publishing: 1] [Article Influence: 0.2] [Reference Citation Analysis]
16 Park SH, Park HM, Baek KR, Ahn HM, Lee IY, Son GM. Artificial intelligence based real-time microcirculation analysis system for laparoscopic colorectal surgery. World J Gastroenterol 2020; 26(44): 6945-6962 [PMID: 33311942 DOI: 10.3748/wjg.v26.i44.6945] [Cited by in CrossRef: 5] [Cited by in F6Publishing: 4] [Article Influence: 2.5] [Reference Citation Analysis]
17 Nakashima K, Ryu S, Okamoto A, Hara K, Ishida K, Ito R, Nakabayashi Y. Intestinal blood flow evaluation using the indocyanine green fluorescence imaging method in a case of incarcerated obturator hernia: A case report. Asian J Endosc Surg 2021;14:565-9. [PMID: 33029854 DOI: 10.1111/ases.12875] [Cited by in Crossref: 3] [Cited by in F6Publishing: 1] [Article Influence: 1.5] [Reference Citation Analysis]
18 Egi H, Ohnishi K, Akita S, Sugishita H, Ogi Y, Yoshida M, Koga S, Kikuchi S, Matsumoto H, Kuwabara J, Matsui S, Ishimaru K, Hattori M, Watanabe Y. The arrival time of indocyanine green in tissues can be a quantitative index because of its correlation with tissue oxygen saturation: A clinical pilot study. Asian J Endosc Surg 2021. [PMID: 34672106 DOI: 10.1111/ases.13002] [Reference Citation Analysis]
19 Son GM, Kwon MS, Kim Y, Kim J, Kim SH, Lee JW. Quantitative analysis of colon perfusion pattern using indocyanine green (ICG) angiography in laparoscopic colorectal surgery. Surg Endosc. 2019;33:1640-1649. [PMID: 30203201 DOI: 10.1007/s00464-018-6439-y] [Cited by in Crossref: 58] [Cited by in F6Publishing: 49] [Article Influence: 14.5] [Reference Citation Analysis]
20 Kojima S, Sakamoto T, Matsui Y, Nambu K, Masamune K. Clinical efficacy of bowel perfusion assessment during laparoscopic colorectal resection using laser speckle contrast imaging: A matched case-control study. Asian J Endosc Surg 2020;13:329-35. [PMID: 31691522 DOI: 10.1111/ases.12759] [Cited by in Crossref: 3] [Cited by in F6Publishing: 2] [Article Influence: 1.0] [Reference Citation Analysis]
21 Chadi SA, Fingerhut A, Berho M, DeMeester SR, Fleshman JW, Hyman NH, Margolin DA, Martz JE, McLemore EC, Molena D, Newman MI, Rafferty JF, Safar B, Senagore AJ, Zmora O, Wexner SD. Emerging Trends in the Etiology, Prevention, and Treatment of Gastrointestinal Anastomotic Leakage. J Gastrointest Surg. 2016;20:2035-2051. [PMID: 27638764 DOI: 10.1007/s11605-016-3255-3] [Cited by in Crossref: 82] [Cited by in F6Publishing: 58] [Article Influence: 13.7] [Reference Citation Analysis]
22 Chang YK, Foo CC, Yip J, Wei R, Ng KK, Lo O, Choi HK, Law WL. The impact of indocyanine-green fluorescence angiogram on colorectal resection. The Surgeon 2019;17:270-6. [DOI: 10.1016/j.surge.2018.08.006] [Cited by in Crossref: 16] [Cited by in F6Publishing: 15] [Article Influence: 5.3] [Reference Citation Analysis]
23 Daskalopoulou D, Kankam J, Plambeck J, Ambe PC, Zarras K. Intraoperative real-time fluorescence angiography with indocyanine green for evaluation of intestinal viability during surgery for an incarcerated obturator hernia: a case report. Patient Saf Surg 2018;12:24. [PMID: 30154915 DOI: 10.1186/s13037-018-0173-1] [Cited by in Crossref: 10] [Cited by in F6Publishing: 7] [Article Influence: 2.5] [Reference Citation Analysis]
24 Kawada K, Hasegawa S, Wada T, Takahashi R, Hisamori S, Hida K, Sakai Y. Evaluation of intestinal perfusion by ICG fluorescence imaging in laparoscopic colorectal surgery with DST anastomosis. Surg Endosc. 2017;31:1061-1069. [PMID: 27351656 DOI: 10.1007/s00464-016-5064-x] [Cited by in Crossref: 58] [Cited by in F6Publishing: 51] [Article Influence: 9.7] [Reference Citation Analysis]
25 Bobel MC, Altman A, Gaertner WB. Immunofluorescence in Robotic Colon and Rectal Surgery. Clin Colon Rectal Surg 2021;34:338-44. [PMID: 34504405 DOI: 10.1055/s-0041-1729866] [Reference Citation Analysis]
26 Ushijima H, Kawamura J, Ueda K, Yane Y, Yoshioka Y, Daito K, Tokoro T, Hida JI, Okuno K. Visualization of lymphatic flow in laparoscopic colon cancer surgery using indocyanine green fluorescence imaging. Sci Rep 2020;10:14274. [PMID: 32868829 DOI: 10.1038/s41598-020-71215-3] [Cited by in Crossref: 1] [Cited by in F6Publishing: 1] [Article Influence: 0.5] [Reference Citation Analysis]
27 Degett TH, Andersen HS, Gögenur I. Indocyanine green fluorescence angiography for intraoperative assessment of gastrointestinal anastomotic perfusion: a systematic review of clinical trials. Langenbecks Arch Surg. 2016; Epub ahead of print. [PMID: 26968863 DOI: 10.1007/s00423-016-1400-9] [Cited by in Crossref: 95] [Cited by in F6Publishing: 80] [Article Influence: 15.8] [Reference Citation Analysis]
28 Clifford RE, Fowler H, Manu N, Sutton P, Vimalachandran D. Intra-operative assessment of left-sided colorectal anastomotic integrity: a systematic review of available techniques. Colorectal Dis 2021;23:582-91. [PMID: 32978892 DOI: 10.1111/codi.15380] [Cited by in Crossref: 2] [Cited by in F6Publishing: 1] [Article Influence: 1.0] [Reference Citation Analysis]
29 Shiga M, Maeda H, Oba K, Okamoto K, Namikawa T, Fujisawa K, Yokota K, Kobayashi M, Hanazaki K. Safety of laparoscopic surgery for colorectal cancer in patients over 80 years old: a propensity score matching study. Surg Today 2017;47:951-8. [PMID: 28130643 DOI: 10.1007/s00595-017-1470-5] [Cited by in Crossref: 15] [Cited by in F6Publishing: 11] [Article Influence: 3.0] [Reference Citation Analysis]
30 Mizrahi I, Wexner SD. Clinical role of fluorescence imaging in colorectal surgery - a review. Expert Rev Med Devices. 2017;14:75-82. [PMID: 27899040 DOI: 10.1080/17434440.2017.1265444] [Cited by in Crossref: 23] [Cited by in F6Publishing: 21] [Article Influence: 3.8] [Reference Citation Analysis]
31 Ianieri MM, Della Corte L, Campolo F, Cosentino F, Catena U, Bifulco G, Scambia G. Indocyanine green in the surgical management of endometriosis: A systematic review. Acta Obstet Gynecol Scand 2021;100:189-99. [PMID: 32895911 DOI: 10.1111/aogs.13971] [Reference Citation Analysis]
32 van Manen L, Handgraaf HJM, Diana M, Dijkstra J, Ishizawa T, Vahrmeijer AL, Mieog JSD. A practical guide for the use of indocyanine green and methylene blue in fluorescence-guided abdominal surgery. J Surg Oncol 2018;118:283-300. [PMID: 29938401 DOI: 10.1002/jso.25105] [Cited by in Crossref: 90] [Cited by in F6Publishing: 75] [Article Influence: 22.5] [Reference Citation Analysis]