BPG is committed to discovery and dissemination of knowledge
Cited by in F6Publishing
For: Seichter F, Wilk A, Wörle K, Kim SS, Vogt JA, Wachter U, Radermacher P, Mizaikoff B. Multivariate determination of 13CO2/12CO2 ratios in exhaled mouse breath with mid-infrared hollow waveguide gas sensors. Anal Bioanal Chem 2013;405:4945-51. [PMID: 23503745 DOI: 10.1007/s00216-013-6824-2] [Cited by in Crossref: 23] [Cited by in F6Publishing: 19] [Article Influence: 2.6] [Reference Citation Analysis]
Number Citing Articles
1 Kokoric V, Theisen J, Wilk A, Penisson C, Bernard G, Mizaikoff B, Gabriel JP. Determining the Partial Pressure of Volatile Components via Substrate-Integrated Hollow Waveguide Infrared Spectroscopy with Integrated Microfluidics. Anal Chem 2018;90:4445-51. [DOI: 10.1021/acs.analchem.7b04425] [Cited by in Crossref: 15] [Cited by in F6Publishing: 7] [Article Influence: 3.8] [Reference Citation Analysis]
2 Perez-guaita D, Garrigues S, de la M, Guardia. Infrared-based quantification of clinical parameters. TrAC Trends in Analytical Chemistry 2014;62:93-105. [DOI: 10.1016/j.trac.2014.06.012] [Cited by in Crossref: 35] [Cited by in F6Publishing: 20] [Article Influence: 4.4] [Reference Citation Analysis]
3 Kokoric V, Widmann D, Wittmann M, Behm RJ, Mizaikoff B. Infrared spectroscopy via substrate-integrated hollow waveguides: a powerful tool in catalysis research. Analyst 2016;141:5990-5. [DOI: 10.1039/c6an01534d] [Cited by in Crossref: 11] [Article Influence: 1.8] [Reference Citation Analysis]
4 Seichter F, Vogt JA, Wachter U, Radermacher P, Mizaikoff B. Strategies for 13C enrichment calculation in Fourier-transform infrared CO2 spectra containing spectral overlapping and nonlinear abundance-amount relations utilizing response surface fits. Analytica Chimica Acta 2020;1095:48-60. [DOI: 10.1016/j.aca.2019.10.038] [Cited by in Crossref: 2] [Cited by in F6Publishing: 2] [Article Influence: 1.0] [Reference Citation Analysis]
5 Müller CM, Pejcic B, Esteban L, Delle Piane C, Raven M, Mizaikoff B. Infrared attenuated total reflectance spectroscopy: an innovative strategy for analyzing mineral components in energy relevant systems. Sci Rep 2014;4:6764. [PMID: 25358261 DOI: 10.1038/srep06764] [Cited by in Crossref: 71] [Cited by in F6Publishing: 27] [Article Influence: 8.9] [Reference Citation Analysis]
6 Stach R, Haas J, Tütüncü E, Daboss S, Kranz C, Mizaikoff B. polyHWG: 3D Printed Substrate-Integrated Hollow Waveguides for Mid-Infrared Gas Sensing. ACS Sens 2017;2:1700-5. [PMID: 29090579 DOI: 10.1021/acssensors.7b00649] [Cited by in Crossref: 8] [Cited by in F6Publishing: 3] [Article Influence: 1.6] [Reference Citation Analysis]
7 Glöckler J, Jaeschke C, Kocaöz Y, Kokoric V, Tütüncü E, Mitrovics J, Mizaikoff B. iHWG-MOX: A Hybrid Breath Analysis System via the Combination of Substrate-Integrated Hollow Waveguide Infrared Spectroscopy with Metal Oxide Gas Sensors. ACS Sens 2020;5:1033-9. [DOI: 10.1021/acssensors.9b02554] [Cited by in Crossref: 8] [Cited by in F6Publishing: 2] [Article Influence: 4.0] [Reference Citation Analysis]
8 Libardi SH, Skibsted LH, Cardoso DR. Oxidation of carbon monoxide by perferrylmyoglobin. J Agric Food Chem 2014;62:1950-5. [PMID: 24506496 DOI: 10.1021/jf4053176] [Cited by in Crossref: 10] [Cited by in F6Publishing: 7] [Article Influence: 1.3] [Reference Citation Analysis]
9 Tütüncü E, Kokoric V, Wilk A, Seichter F, Schmid M, Hunt WE, Manuel AM, Mirkarimi P, Alameda JB, Carter JC, Mizaikoff B. Fiber-Coupled Substrate-Integrated Hollow Waveguides: An Innovative Approach to Mid-infrared Remote Gas Sensors. ACS Sens 2017;2:1287-93. [PMID: 28792208 DOI: 10.1021/acssensors.7b00253] [Cited by in Crossref: 14] [Cited by in F6Publishing: 5] [Article Influence: 2.8] [Reference Citation Analysis]
10 Seichter F, Vogt J, Radermacher P, Mizaikoff B. Nonlinear calibration transfer based on hierarchical Bayesian models and Lagrange Multipliers: Error bounds of estimates via Monte Carlo – Markov Chain sampling. Analytica Chimica Acta 2017;951:32-45. [DOI: 10.1016/j.aca.2016.11.025] [Cited by in Crossref: 8] [Cited by in F6Publishing: 6] [Article Influence: 1.6] [Reference Citation Analysis]
11 Zhou T, Wu T, Wu Q, Ye C, Hu R, Chen W, He X. Real-time measurement of CO2 isotopologue ratios in exhaled breath by a hollow waveguide based mid-infrared gas sensor. Opt Express 2020;28:10970-80. [PMID: 32403618 DOI: 10.1364/OE.385103] [Cited by in Crossref: 7] [Cited by in F6Publishing: 2] [Article Influence: 7.0] [Reference Citation Analysis]
12 Perez-Guaita D, Kokoric V, Wilk A, Garrigues S, Mizaikoff B. Towards the determination of isoprene in human breath using substrate-integrated hollow waveguide mid-infrared sensors. J Breath Res 2014;8:026003. [PMID: 24848160 DOI: 10.1088/1752-7155/8/2/026003] [Cited by in Crossref: 32] [Cited by in F6Publishing: 20] [Article Influence: 4.0] [Reference Citation Analysis]
13 Wilk A, Carter JC, Chrisp M, Manuel AM, Mirkarimi P, Alameda JB, Mizaikoff B. Substrate-Integrated Hollow Waveguides: A New Level of Integration in Mid-Infrared Gas Sensing. Anal Chem 2013;85:11205-10. [DOI: 10.1021/ac402391m] [Cited by in Crossref: 63] [Cited by in F6Publishing: 42] [Article Influence: 7.0] [Reference Citation Analysis]
14 Wallace MAG, Pleil JD. Evolution of clinical and environmental health applications of exhaled breath research: Review of methods and instrumentation for gas-phase, condensate, and aerosols. Anal Chim Acta 2018;1024:18-38. [PMID: 29776545 DOI: 10.1016/j.aca.2018.01.069] [Cited by in Crossref: 44] [Cited by in F6Publishing: 34] [Article Influence: 11.0] [Reference Citation Analysis]
15 Perez-guaita D, Wilk A, Kuligowski J, Quintás G, de la Guardia M, Mizaikoff B. Improving the performance of hollow waveguide-based infrared gas sensors via tailored chemometrics. Anal Bioanal Chem 2013;405:8223-32. [DOI: 10.1007/s00216-013-7230-5] [Cited by in Crossref: 9] [Cited by in F6Publishing: 5] [Article Influence: 1.0] [Reference Citation Analysis]
16 Liu Y, Wu T, Wu Q, Chen W, Ye C, Wang M, He X. A Laser-Locked Hollow Waveguide Gas Sensor for Simultaneous Measurements of CO2 Isotopologues with High Accuracy, Precision, and Sensitivity. Anal Chem 2021;93:15468-73. [PMID: 34766749 DOI: 10.1021/acs.analchem.1c03482] [Reference Citation Analysis]
17 Fortes PR, da Silveira Petruci JF, Wilk A, Cardoso AA, Raimundo Jr IM, Mizaikoff B. Optimized design of substrate-integrated hollow waveguides for mid-infrared gas analyzers. J Opt 2014;16:094006. [DOI: 10.1088/2040-8978/16/9/094006] [Cited by in Crossref: 16] [Cited by in F6Publishing: 4] [Article Influence: 2.0] [Reference Citation Analysis]
18 Tütüncü E, Nägele M, Becker S, Fischer M, Koeth J, Wolf C, Köstler S, Ribitsch V, Teuber A, Gröger M, Kress S, Wepler M, Wachter U, Vogt J, Radermacher P, Mizaikoff B. Advanced Photonic Sensors Based on Interband Cascade Lasers for Real-Time Mouse Breath Analysis. ACS Sens 2018;3:1743-9. [DOI: 10.1021/acssensors.8b00477] [Cited by in Crossref: 8] [Cited by in F6Publishing: 6] [Article Influence: 2.0] [Reference Citation Analysis]
19 Dong B, Luo X, Zhu S, Hu T, Li M, Hasan D, Zhang L, Chua SJ, Wei J, Chang Y, Ma Y, Vachon P, Lo GQ, Ang KW, Kwong DL, Lee C. Thermal annealing study of the mid-infrared aluminum nitride on insulator (AlNOI) photonics platform. Opt Express 2019;27:19815-26. [PMID: 31503736 DOI: 10.1364/OE.27.019815] [Cited by in Crossref: 14] [Cited by in F6Publishing: 3] [Article Influence: 4.7] [Reference Citation Analysis]
20 Mizaikoff B. Waveguide-enhanced mid-infrared chem/bio sensors. Chem Soc Rev 2013;42:8683-99. [PMID: 23995692 DOI: 10.1039/c3cs60173k] [Cited by in Crossref: 104] [Cited by in F6Publishing: 64] [Article Influence: 13.0] [Reference Citation Analysis]